13
This code is valid 30 seconds from Arming. After 30 seconds, the code is not valid. Entering
code No. 8 will delete zone bypasses including auto-bypass.
3.
Code number 9, Programming Code (Installer Code). This code enables entering the
programming mode (system features programming) at the Installer level.
The factory default programming code is ‘1 9 9 4’.
The programming code may be installer-programmed. Installer Code does not Arm or
Disarm system.
4.
User Codes - (Arming/Disarming code); each code is 1 to 6 digit. System provides eight
users programmable codes.
13
.
Remote Key and Wireless Arming & Disarming
The AV-2004/48 enables Arming and Disarming by remote momentary or latch key-switch (as
programmed in address 071-
7), which is connected to JP1 ‘KEY’ and ‘
- Aux. Power (Refer to
Wiring Diagram). Cable set for connecting to JP1 requires order separately.
When using remote key-switch, wire length should not exceed 10 meters.
A Momentary pulse (momentary trig) between ‘KEY’ terminals will Arm and Disarm the control
panel (close the ‘instant’ and ‘24H’ zones Prior to arming.)
System reverts to previous status with next momentary pulse. (Refer to Wiring Diagram.)
For Arming/Dis
arming via Wireless Radio Remote, connect receiver's relay to ‘KE’ and ‘
-Aux.
Power’ terminals. Verify the receiver relay mode, momentary, or latch, and set system
accordingly.
For fast Remote Key wiring, the AV-2004/48/M contains a fast-insert connection, a dedicated
wired connector is available (not included in the standard AV-2004 and AV-2048).
In most cases the Key connector is applicable for emergency Disarming
–
Short the key terminal
with screwdriver. For remote arming with wireless remote transmitter use the A..RX and AVS22.
Starting version 3.04: Zone 4 or 8 may function as auxiliary remote key input, programmable at
address 050-3. The Aux. key Arms without Home (group) mode, sounds siren beep when Arming
(if programmed), sounds siren beeps when Disarming (if programmed).
14. Remote Access via DTMF
General Description
Starting generation III alarm panels (“D” suffix) includes the added functions for remote control
via DTMF phone. DTMF commands are possible when the panel call your phone, or by calling
the panel. The DTMF remote control functions:
Check the status of the control panel (Armed/Disarm, Alarm in progress)
Arm or disarm the control panel
Bypass zones or clear all bypassed zones
Stop the dialer report during alarm
Momentary activate A1 (alarm) output for three seconds
First Alarm indication - by a number of beeps per zone, special tune for Panic alarm
The same options are available when a call is received from the control panel during an alarm
condition.