8. TELEPHONE LINE WIRING and PROGRAMMING
It’s recommended to connect the control panel to an independent telephone line, if a device is in
parallel with the alarm panel, this may grab the call first (like a message answer/fax) during
remote up and download. Don’t connect fax or answering machine in parallel on the same
telephone line.
Default dialing mode is DTMF. If Pulse dial is selected, the default is European Make/Break rate
of 40/60 milliseconds (in Pulse dialing).
Dialing mode is programmable (refer to programming sheet addresses 084).
Connect the telephone line to ‘TEL
-
LINE’ terminal, if handsets connected to same line connect
them to ‘PHONES’, when system attempts to dial the ‘PHONES’ is disconnected.
Do not connect to ISDN or other digital telephone system. Most ISDN converters contain an
Analog line; connect the Analog line of the ISDN to the panel TEL-LINE terminal. For
DSL/ADSL connect a dedicated lien filter supplied by local Telecom Company.
9. BEFORE POWERING UP
Place Control Panel in a well-ventilated location, and as far as possible from any heat source.
Do not place high power RF wireless transmitters near Control Panel.
Check for proper grounding.
Make sure detectors, keypads or any other devices are connected to the Control Panel in
their correct polarities.
Connect a momentary voltage to the siren; making sure a ‘beep’ is sounded. In case of no
beep, check for a short circuit or improperly connected wires.
Power-up through transformer, if system seems to operate properly connect the battery.
Do not connect any sensors or other devices to the battery terminals.
The AV-2004/48 are compatible with 12V smoke detectors, common collector type or relay
(-) output on alarm.
In the AV-2004/48, a momentary switch achieves smoke detector reset. The switch (or relay)
disconnects power to smoke detector following a smoke alarm.
10. AV-2004/48 STANDARD KEYPAD FUNCTIONS
Common Terms in this Manual
‘SHUNT’
‘BYPASS’ are interchangeable terms
Program Mode
Provides features programming, ‘P’ is displayed, alarm is disabled
Use Mode
Normal operation mode
AV-701
AV-701T
AV-701TI
AV-702 are identical and interchangeable term