AV-GAD EasyLoader AV-2004 Installation And Operation Manual Download Page 20

20

Restore Codes - Single Codes

Restore Codes - Single Codes

1

2

3

4

Z O N E S

AC LB PA

142 144 146 148

158 160 162

E

E

E

E

CODES

E

E

E

143 145 147 149

159 161 163

1

2

3

4

CODES

9

B

A

Restore Codes - Extended or 2 Digits

Restore Codes - Extended or 2 Digits

Bypassed Zones Codes - Single Codes

Reserved

1

2

3

4

Z O N E S

174 176 178 180

8

8

8

8

CODES

175 177 179 181

1

2

3

4

CODES

Bypassed Zones - Extended or 2 Digits

Closing (Arming) Codes-Single Digit

Opening (Disarming) Codes-Single Digit

Single Digit

1

2

3

4

Test

 USER

1

2

3

4

Test

Force

Opening

220 222 224 226

236

238 240 242 244

254

256

C

C

C

C

A

CODE

B

B

B

B

D

221 223 225 227

237

239 241 243 245

255

257

1

2

3

4

9

CODE

1

2

3

4

9

Closing Codes - Extended or 2 Digits

Opening Codes - Extended or 2 Digits

In order to disable reporting Closing/Opening change program at address

072; remove value ’3’.

When SIGNAL TEST is enabled, you can specify to report System Status (as default for Extended or 2 digits) by programming for example

‘A’ (Armed) at 236, and ‘D’ (Disarmed) at 254, ‘9’ is the test signal code. For System Status repo

rt, select extended or two digits format.

For programming the End-User codes 1 to 8 (Arm/Disarm code) via installer programming mode, enter to address No. 099,
then program new codes by first entering the code index (1,2,3..).
For Force Opening Code (Ambush) the user should enter the Disarming code in reverse order.



 TEL. 2 - SUBSCRIBER ID NUMBER

Note: For subscriber ID that contains a ‘0’ (zero), enter 10 in place of 0. ‘0’ will be displayed as ‘A.’

Do not enter 0 0.

Group 1

Group 2

Alarm / Restore ID Alarm / Restore ID Open. / Closing ID

260 261 262 263 268 269 270 271 276 277 278 279

To easily program the subscriber ID number, as a sequence of 4 digits use the EASY Program.
Even if your code is 3 digits only you must enter 4 digits, the 4th digit can be any digit and the system will disregard the 4th digit.

EASY Program

EASY Program

EASY Program

Alarm / Restore ID Alarm / Restore ID Open. / Closing ID

360

368

376

Summary of Contents for EasyLoader AV-2004

Page 1: ...tor Year 2000 ready Express Installation and Operation Manual Version 3 06 with very slow zone Edition II This product is subject to continual enhancement and therefore specifications may be changed o...

Page 2: ...ntrol of output A1 Version 3 02 First alarm indication by DTMF A1 at Latch mode Version 3 04 New at 072 4 activate ON output to drive ADSL filter line disconnect added 999 to exit programming mode dur...

Page 3: ...ram is set at non EOL for all zones To select EOL mode enter at address 029 the required zone to be EOL or enter 0 to enable all zones as EOL Note Address 029 at the AV 2048 is blocked Only EOL mode i...

Page 4: ...en using few keypads connect them in parallel Each keypad has four terminal wires Power connect to Aux Power System Data connect to OR Power connect to Aux Power System Strobe connect to YE 7 4 1 0 8...

Page 5: ...is factory default in Siren mode install only speaker type sirens which DO NOT contain sound driver or electronic modules The alarm issued by the siren differs according to the type of zone Bell Mode...

Page 6: ...ground properly check that ground does not transfer high voltages 7 BACK UP BATTERY Make sure to connect the Battery in the correct polarity The system s Red wire is the positive pole and the Black w...

Page 7: ...ORE POWERING UP Place Control Panel in a well ventilated location and as far as possible from any heat source Do not place high power RF wireless transmitters near Control Panel Check for proper groun...

Page 8: ...n AV 2048 Arming with Group Bypass 2nd Group Bypass added address 034 and the procedure enhanced after selecting the Group Bypass system is armed without code entry To bypass 1st group Press 0 and hol...

Page 9: ...the function chime mode is not affected by Arm Disarm Chime mode is confirmed by c display on keypad 6 Telephone Key 6 DIALER TEST FOLLOW ME PROGRAMMING Test is performed in Disarmed mode Function Via...

Page 10: ...isplay Open and close each zone to test A one second beep confirms detection of zone opening Three beeps indicate zone closing Quit Fault Find mode by arming the system 8 Program Key 8 PROGRAM Key 8 a...

Page 11: ...Mode and exit When last event is displayed and attempting to move forward key 2 a blank sign is displayed and a long warning beep indicating that it is the last event Press key 8 to move backward if n...

Page 12: ...played zone H For Silent used with Panic button Panic alarm remove siren and buzzer activation by programming the Panic Zone so Panic zone program as 24H zone type N O type fast response type To quit...

Page 13: ...relay to KE and Aux Power terminals Verify the receiver relay mode momentary or latch and set system accordingly For fast Remote Key wiring the AV 2004 48 M contains a fast insert connection a dedicat...

Page 14: ...user during alarm When the control panel calls the user during alarm it will first generate the siren sound for about 30 seconds to shorten this feature at address 085 Tel Message Time to 30 as defau...

Page 15: ...n tune and will hang up 15 USER CODE PROGRAMMING Set New USER CODE 1 Hold down key 8 Program 2 While 4 LEDs are blinking enter code No 1 default 1 2 3 4 3 If code is valid four LEDs will stop blinking...

Page 16: ...for Automatic Arming By Installer Program or display hours and minutes at address 016 By User Enter to user programming mode Hold down 8 A is displayed type hour and minutes in 24 hours format To dis...

Page 17: ...oup Bypass II 034 Manual Bypass 035 1 2 3 4 5 6 7 8 Siren Out 036 1 2 3 4 5 6 7 8 Alarm 1 A1 Out 037 1 2 3 4 5 6 7 8 Reserved 038 Reserved 039 Dial on Alarm 040 1 2 3 4 5 6 7 8 Sounder on Alarm 041 1...

Page 18: ...1 via DTMF 2 Enable 2048 New Zones Wiring Method 2 Enable Auto reset zone after alarm timeout 3 Reserved 4 Enable Zone at 032 Very slow zone 4 Reserved 5 Enable DTMF control D type or Ver 3 6 Enable B...

Page 19: ...ID or Ademco High Speed 00 No Communicator is identical to Dialer that generates sound upon alarm Contact ID and Ademco H S are available at panels version 2 06 or higher Rnd is shortening for ROUNDS...

Page 20: ...u can specify to report System Status as default for Extended or 2 digits by programming for example A Armed at 236 and D Disarmed at 254 9 is the test signal code For System Status report select exte...

Page 21: ...ay Delete 3 If the code is valid P will be displayed The two left LED s Red Green blink to indicate that system is waiting for a new programming address number 4 Enter address to be programmed see pro...

Page 22: ...value 1 2 3 4 by pressing 1 Siren 2 Shunt Display 3 Status 4 Delay Delete U confirms programming updating 5 P is displayed two left most LEDs are blinking 19 RESET SYSTEM TO DEFAULT PROGRAMMING Warnin...

Page 23: ...Telephone Line Monitor test address 094 Time interval between telephone line tests in hours Range between 00 24 When 00 programmed no test performed Failure to get a dial tone when dialing will cause...

Page 24: ...st and simple programming of EasyLoader panels Programming tables codes and other features may be up downloaded from an on site PC DOS Mode via telephone using Modem and EasyLoad software which is sup...

Page 25: ...ut in text fields by hitting the ENTER return key In order to select the required field hit the highlighted digit or letter Full instructions and latest features are enclosed in the EasyLoad software...

Page 26: ...re servicing this unit 5 Keypad Connect maximum of two AV 701 or four AV 702 keypads 6 Sirens Connect horn type siren speaker If using Bell adhere to maximum ratings For self contain bells program 3 i...

Page 27: ...p Resistor 2 200 Ohms 0 25W 5 AV 2048 2 200 and 4 700 Ohms Auxiliary Power Max 13 6V DC 0 5A Combined AUX Power and Keypad outputs Battery Charging Current Max 550 mA current limited Battery Test Indi...

Page 28: ...ce hereof There is no express or implied warranty of merchantability or a warranty of fitness for particular purpose Additionally this warranty is in lieu of all other obligations or liabilities on th...

Reviews: