 SYSTEM FEATURES

Values marked with ( ) are the factory default programming

Feature

070

Feature

071

Enable-Siren/Bell Test upon Arming

1

Enable-Erase F. Me number on Disarm

1

Enable-Keypad 3 Beeps upon Disarming

(2)

Enable-Instant Arming via Key 5

2

Enable-Buzzer upon Entry Delay

(3)

Enable-Buzzer during exit delay

3

Enable-Keypad Tactile Beep

(4)

Enable-Display Alarmed Zone during alarm

4

Disable-4 LEDs display during Armed

5

Enable-Manual Bypass via Code No .1

5

Enable-Battery Test upon Arming

(6)

Enable-Lock in Armed after Tamper Alarm

6

Reserved

7

Enable-Momentary Key-Switch

(7)

Enable-Keypad Panic

(8)

Enable-

Code ‘8’ as one time code

8

Feature

072

Feature

073

Enable-Bell mode

(1)

Enable-Display troubled zones at Disarmed

(1)

Enable-Detailed alarm history

(2)

Enable-Test to central station each hour

2

Enable-Report Opening/Closing

(3)

Enable-Self contain Bell (0V at alarm) **

3

Activate ON output for ADSL filter line-cut

4

Reserved

4

Enable-Report bypassed zones at Arming

5

Enable- Group Bypass when Arm with Key

5

Enable-Exit delay when delayed zones clear

6

Enable - 2 Siren Beeps at Key Disarming

6

Enable -

’ON’ output as SVM trigger *

7

Enable - A1 output time follows Siren time

(7)

Enable-codes reset to default by * & #

(8)

Enable - Outputs (A1, ON) 0V at active

8

Feature

074

Feature

075

Reserved

1

Enable

 K. Pad & Sir sounds @ Home mod

1

Enable-Activate A1 via DTMF

2

Enable

 2048 New Zones Wiring Method

2

Enable-Auto reset zone after alarm timeout

3

Reserved

4

Enable

– Zone at 032 “Very slow zone”

4

Reserved

5

Enable

 DTMF control (D type or Ver. 3)

(6)

Enable

 Bypass Answer Machine

7

Enable-Echo Cancellation Tone (AUSTEL)

8

Enable - A1 output as Latching

8

* AV-2004D starting January 2005. ** Self-contained Bell is operative if Bell mode selected

 DIAL PARAMETERS

Pre-Dial

Delay

Wait

for Dial

Tone

Anti-Jam

Delay

Dial tone
detection

Dial

Mode

Tel.

MSG
Time

Inter-

Call

Delay

Re-Dial

Cycles
(max.)

Pulse

MAKE

Pulse

BREAK

Inter

Digit

Delay

Rings

qut'y for

modem

Instant

modem

answer

Ring

Cycle

Width

Sec's

Sec's

Sec's

00=No

01=Yes

0=Pulses

1=DTMF

Sec's

Sec's

XX Cycle 5 mS

5 mS

50 mS

Tel.

Rings

00=No

01=Yes

100 mS

(1-25)

080

081

082

083

084

085

086

087

088

089

090

091

092

093

0

3

0

4

1

0

0

1

0

1

5

0

2

0

0

3

0

8

1

2

2

0

1

0

0

1

2

0

Tel.

Line

Test

Intervals

Min.
Ring

Length

Rings

Time

Out

Minutes

(Max 99)

10 mS

(Max 20)

Seconds

(4 to 25)

094

095

096

0

0

1

5

0

6

Note address 091: The download is ENABLED by default. Setting 21 at address 091 disable modem (because 21 rings for modem not accepted by
telephone net). To ENABLE enter 01 to 20 at address 091. For Instant Modem Answer (Answer Now): Enter 01 in address 092, hold-down key 6
then hold-down key 1,

‘A’ displayed in confirmation. For special application, address 093 set the ring detector pulse width.

SET USER CODES: Address 099 provides setting of user codes 1 to 8.

SET FACTORY DEFAULT: In address 200 enter 6 9, program will revert to factory default programming

Summary of Contents for EasyLoader AV-2004

Page 1: ...tor Year 2000 ready Express Installation and Operation Manual Version 3 06 with very slow zone Edition II This product is subject to continual enhancement and therefore specifications may be changed o...

Page 2: ...ntrol of output A1 Version 3 02 First alarm indication by DTMF A1 at Latch mode Version 3 04 New at 072 4 activate ON output to drive ADSL filter line disconnect added 999 to exit programming mode dur...

Page 3: ...ram is set at non EOL for all zones To select EOL mode enter at address 029 the required zone to be EOL or enter 0 to enable all zones as EOL Note Address 029 at the AV 2048 is blocked Only EOL mode i...

Page 4: ...en using few keypads connect them in parallel Each keypad has four terminal wires Power connect to Aux Power System Data connect to OR Power connect to Aux Power System Strobe connect to YE 7 4 1 0 8...

Page 5: ...is factory default in Siren mode install only speaker type sirens which DO NOT contain sound driver or electronic modules The alarm issued by the siren differs according to the type of zone Bell Mode...

Page 6: ...ground properly check that ground does not transfer high voltages 7 BACK UP BATTERY Make sure to connect the Battery in the correct polarity The system s Red wire is the positive pole and the Black w...

Page 7: ...ORE POWERING UP Place Control Panel in a well ventilated location and as far as possible from any heat source Do not place high power RF wireless transmitters near Control Panel Check for proper groun...

Page 8: ...n AV 2048 Arming with Group Bypass 2nd Group Bypass added address 034 and the procedure enhanced after selecting the Group Bypass system is armed without code entry To bypass 1st group Press 0 and hol...

Page 9: ...the function chime mode is not affected by Arm Disarm Chime mode is confirmed by c display on keypad 6 Telephone Key 6 DIALER TEST FOLLOW ME PROGRAMMING Test is performed in Disarmed mode Function Via...

Page 10: ...isplay Open and close each zone to test A one second beep confirms detection of zone opening Three beeps indicate zone closing Quit Fault Find mode by arming the system 8 Program Key 8 PROGRAM Key 8 a...

Page 11: ...Mode and exit When last event is displayed and attempting to move forward key 2 a blank sign is displayed and a long warning beep indicating that it is the last event Press key 8 to move backward if n...

Page 12: ...played zone H For Silent used with Panic button Panic alarm remove siren and buzzer activation by programming the Panic Zone so Panic zone program as 24H zone type N O type fast response type To quit...

Page 13: ...relay to KE and Aux Power terminals Verify the receiver relay mode momentary or latch and set system accordingly For fast Remote Key wiring the AV 2004 48 M contains a fast insert connection a dedicat...

Page 14: ...user during alarm When the control panel calls the user during alarm it will first generate the siren sound for about 30 seconds to shorten this feature at address 085 Tel Message Time to 30 as defau...

Page 15: ...n tune and will hang up 15 USER CODE PROGRAMMING Set New USER CODE 1 Hold down key 8 Program 2 While 4 LEDs are blinking enter code No 1 default 1 2 3 4 3 If code is valid four LEDs will stop blinking...

Page 16: ...for Automatic Arming By Installer Program or display hours and minutes at address 016 By User Enter to user programming mode Hold down 8 A is displayed type hour and minutes in 24 hours format To dis...

Page 17: ...oup Bypass II 034 Manual Bypass 035 1 2 3 4 5 6 7 8 Siren Out 036 1 2 3 4 5 6 7 8 Alarm 1 A1 Out 037 1 2 3 4 5 6 7 8 Reserved 038 Reserved 039 Dial on Alarm 040 1 2 3 4 5 6 7 8 Sounder on Alarm 041 1...

Page 18: ...1 via DTMF 2 Enable 2048 New Zones Wiring Method 2 Enable Auto reset zone after alarm timeout 3 Reserved 4 Enable Zone at 032 Very slow zone 4 Reserved 5 Enable DTMF control D type or Ver 3 6 Enable B...

Page 19: ...ID or Ademco High Speed 00 No Communicator is identical to Dialer that generates sound upon alarm Contact ID and Ademco H S are available at panels version 2 06 or higher Rnd is shortening for ROUNDS...

Page 20: ...u can specify to report System Status as default for Extended or 2 digits by programming for example A Armed at 236 and D Disarmed at 254 9 is the test signal code For System Status report select exte...

Page 21: ...ay Delete 3 If the code is valid P will be displayed The two left LED s Red Green blink to indicate that system is waiting for a new programming address number 4 Enter address to be programmed see pro...

Page 22: ...value 1 2 3 4 by pressing 1 Siren 2 Shunt Display 3 Status 4 Delay Delete U confirms programming updating 5 P is displayed two left most LEDs are blinking 19 RESET SYSTEM TO DEFAULT PROGRAMMING Warnin...

Page 23: ...Telephone Line Monitor test address 094 Time interval between telephone line tests in hours Range between 00 24 When 00 programmed no test performed Failure to get a dial tone when dialing will cause...

Page 24: ...st and simple programming of EasyLoader panels Programming tables codes and other features may be up downloaded from an on site PC DOS Mode via telephone using Modem and EasyLoad software which is sup...

Page 25: ...ut in text fields by hitting the ENTER return key In order to select the required field hit the highlighted digit or letter Full instructions and latest features are enclosed in the EasyLoad software...

Page 26: ...re servicing this unit 5 Keypad Connect maximum of two AV 701 or four AV 702 keypads 6 Sirens Connect horn type siren speaker If using Bell adhere to maximum ratings For self contain bells program 3 i...

Page 27: ...p Resistor 2 200 Ohms 0 25W 5 AV 2048 2 200 and 4 700 Ohms Auxiliary Power Max 13 6V DC 0 5A Combined AUX Power and Keypad outputs Battery Charging Current Max 550 mA current limited Battery Test Indi...

Page 28: ...ce hereof There is no express or implied warranty of merchantability or a warranty of fitness for particular purpose Additionally this warranty is in lieu of all other obligations or liabilities on th...

Reviews: