10 Program Instructions
© Copyright Reserved Autonics Co., Ltd.
77
10.1.2
INC (Incremental Position Move)
It is for moving to incremental position by a specified distance from current position.
Instruction DATA
INC
Instruction Start speed Max speed Acceleration Deceleration Position
For more information, refer to the ‘11.1.1 Fixed Pulse and Continuous Pulse Drive’.
Start speed
: Select the start drive speed.
Set the start speed from 1 to 5 according to purpose.
When selecting ‘User Value’, it is available to set as the desired value.
Max speed
: Select the max. drive speed during drive.
Set the max. speed from 1 to 5 according to purpose.
When selecting ‘User Value’, it is available to set as the desired value.
Acceleration
: Set the acceleration time of drive.
Set the acceleration time 1 to 5 according to purpose.
When selecting ‘User Value’, it is available to set as the desired value.
Deceleration
: Set the deceleration time of drive.
Set the deceleration time 1 to 5 according to purpose.
When selecting ‘User Value’, it is available to set as the desired value.
Position
: Input the moving position as absolute value.
Available moving range is -2,147,483,648 to 2,147,483,647.