2 Specification
22
© Copyright Reserved Autonics Co., Ltd.
※
8
: □
of model name indicates cable length (1, 2, 3, 5, 7, 10, 15, 20).
(B) of model name indicates the built-in brake type, none indicates the standard type.
E.g.) C1DF14MB-10: 10 m moving type, built-in brake type motor+encoder cable.
※
9: The weight includes packaging. The weight in parenthesis is for unit only.
※
Environment resistance is rated at no freezing or condensation.
2.2
CC-Link Communication
Comm. standard
CC-Link Ver.1.10
Station type
Remote Device station
Connection cable
CC-Link dedicated cable
Comm. speed
156k, 625k, 2.5M, 5M, 10M bps
Station number
01 to 64
Number of occupied stations
1 station occupied,
2 stations occupied
Max. transmit distance
Depend on comm. speed
Remote I/O
● 1
station occupied: Ryn/RXn 32 points each
● 2
stations occupied: Ryn/RXn 64 points each
Remote register
● 1
station occupied: RWrn/RWwn 4 words each
● 2
stations occupied: RWrn/RWwn 8 words each
Command
Point table read/write, parameter read/write, read only,
special command monitor only, network connection, drive control,
motion control, drive status
Comm. setting switch
10 bit rotary switch (0 to 9): 3, 1 bit DIP switch (ON/OFF)
※
It is for parameter setting and monitoring via external devices (PC, PLC, etc.).
※
In CC-Link setting, the communication speed must be same between PLC and the driver.
※
The settable station number is 01 to 64, the station number must not be overlapped.
(65 to 99 is not available)