11 Driver Function
© Copyright Reserved Autonics Co., Ltd.
83
11
Driver Function
11.1
General Drive
11.1.1
Fixed Pulse and Continuous Pulse Drive
Drive pulse output on each axis is basically in ±directions by drive instruction of a fixed or
continuous pulse.
11.1.1.1
Fixed Pulse Drive
Fixed pulse drive is used to move object a fixed amount.
It operates fixed speed or acceleration/deceleration drive for a specified number of output
pulses.
Acceleration/Deceleration fixed pulse drive starts to reduce speed when remaining output
pulse is less than the pulse used for acceleration. It ends drive when it finishes generating
pulse, as shown in the image below.
Absolute position moves and incremental position move
: There are absolute position move and incremental position move.
These are fixed pulse drive.
Absolute position moves drives from home to position of specified distance.
This is only for ABS instruction in program mode.
Incremental position move sets a distance to drive from present coordinates.
INC instruction is corresponding to this program mode.