8
After the authorization (the current PIN-code was
entered) press 10 times any button wired to the
immobilizer entry. Press button not later than 2 minutes
after entering the PIN-code. The interval between the
pressing of the buttons shall not exceed 2 seconds.
The service mode activation will be confirmed by 10
LED or buzzer signals.
The exit from the service mode
is performed by entering
the PIN-code. The 2 times indication signal will confirm
that the service mode is deactivated.
ATTENTION!
Service mode is not disabled when the
power is cut off and the ignition is switched on/off.
Use the emergency authorization code to turn off the
service mode in case of emergency (p. 6).
After the deactivation of the service mode when you
try to switch the ignition on or start the engine you will
have to enter the PIN-code.
Authorization by the PIN-code after the deactivation
of the service mode is not required if the ignition was
switched on then switched off for less than 10 seconds,
and after that switched on again (the module is in
operating mode).