Oscilloscope Operations
Troubleshooting
125
B.
Auto Mode
– configures the trigger to occur every time when the
scope captures the signal waveforms by the preset trigger point.
The scope continues to draw the waveforms even when the signal
is not in the trigger point range.
Main Time Base
– allows users to select an appropriate time per division.
The time per division (10 divisions) is displayed along the bottom of the
screen. The time base adjustment affects all of the active scope
channels at once.
Measure
– allows users to select various types of measurement
parameters to be displayed at the right side of the screen for reference.
A maximum of 5 items each time are allowed to be selected.
To set a specific trigger point
1.
Tap the
Trigger On
button to activate the trigger.
2.
Configures the specific trigger source, the trigger slope and the
trigger mode according to the test demand.
3.
Tap and slide the voltage scale reference line up or down to the
desired voltage point. The voltage info is displayed in a small
reference box.
4.
Tap and slide the time base reference line left or right to the desired
point.
5.
Tap
Start
button on the top right side of the screen to activate the
scope
16.5 Troubleshooting
If the MaxiScope is not communicating with the Display Tablet, you need to do
the followings:
Check if the MaxiScope is properly connected to the Display Tablet
through the supplied USB cable.
If the MaxiScope is already connected to the Display Tablet, but the
communication between the devices has failed, tap the
Scope Icon
on the top right side of the screen to reset the USB connection.