1.  TECHNICAL DATA 

 

 
As a stove of construction type 1, it is possible to connect it to the chimney together with an exisiting other stove or 
another hearth for solid fuels, as long as the chimney dimensioning complies with DIN 4705, Part 3. 
 

 

 

 
*1: A wall installation with a 0 mm distance is only allowed if an insulated flue pipe (insulation min. 4 cm with 
mineral or rock wool (AGI Q 132)) is mounted. 
 

*3 This value applies for a niche installation, without the influence of the glass pane’s front radiation to the 

sides. 
 
*4 This value applies for a ceiling flammable/to be protected and a minimum lateral wall-distance of the 
fireplace of 150 mm. 
 
 
 
 
 
 
 
 
 
 

 

 

Colin 

Jay 

Mel 

Minh 

Rikk 

Sam 

TECHNICAL DATA 

Height

 

1856 mm 

1839 mm 

1861 mm 

1659 mm 

1736 mm 

1639 mm 

Width 

818 mm 

846 mm 

658 mm 

470 mm 

918 mm 

786 mm 

Depth 

591 mm 

626 mm 

763 mm 

474 mm 

591 mm 

530 mm 

Weight 

358/388 kg 

---/413 kg 

367 kg 

200 kg/---  298/342 kg 

265/316 kg 

Flue pipe outlet diameter 

180 mm 

180 mm 

180 mm 

150 mm 

180 mm 

150 mm 

Nominal thermal output (EN 13240)  

8 kW 

9 kW 

10 kW 

5 kW 

10 kW 

6,5 kW 

Maximum thermal capacity 

11 kW 

13 kW 

14 kW 

7 kW 

14 kW 

9 kW 

Smallest heating capacity 

4 kW 

4,5 kW 

5 kW 

2,5 kW 

5 kW 

3,5 kW 

 Room heating capacity  
 (depending on building insulation) 

98 

 225 m³ 

114

305 m³  130

360 m³ 

48 -124 m³ 

130-360 m³ 

72 

 190 m³ 

Exhaust values for multiple use of the chimney in accordance with DIN 4705, Part 3 and for the calculation 
of the chimney measurements in accordance with DIN 4705, Part 2 

Flue gas mass flow closed 

7,74 g/s 

7,21 g/s 

8,2 g/s 

5,0 g/s 

8,13 g/s 

6 g/s 

Flue gas temperature  closed 

298 °C 

341 °C 

250 °C 

273 °C 

313 °C 

326 °C 

Minimum feed pressure closed 
Nominal thermal output 

12 

12 

12 

12 

12 

12 

Minimum feed pressure 
Nominal thermal output 
at 0.8 times n. ther. outp. 

10 

10 

10 

10 

10 

10 

Required safety distances (Minimum distances) - 

 

towards flammable materials 

 toward the front in the radiated area 

800 mm 

in testing 

800 mm 

850 mm 

800 mm 

in testing

 

 to the side 

0mm (*1, 

*3) / 150 

mm 

in testing

 

800 mm 

0 (*1) / 15 

mm 

150 mm 

(*1) 

in testing

 

 to the back 

0 mm (*1) 

in testing

 

0 mm 

0 (*1) / 15 

mm 

0 mm (*1) 

in testing

 

 to the ceiling 

540 mm 

(*4) 

in testing

 

630 mm 

760 mm 

660 mm 

in testing

 

 to the side glass 

 

in testing

 

800 mm 

850 mm 

 

in testing

 

Summary of Contents for Colin

Page 1: ...Benutzerhandbuch manual manuale manuel Benutzerhandbuch user instructions Istruzioni per l uso manuel d instructions Colin Jay Mel Minh Rikk Sam...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...150 mm 180 mm 150 mm Nennw rmeleistung lt EN13240 8 kW 9 kW 10 kW 5 kW 10 kW 6 5 kW Maximale Heizleistung 11 kW 13 kW 14 kW 7 kW 14 kW 9 kW Kleinste Heizleistung 4 kW 4 5 kW 5 kW 2 5 kW 5 kW 3 5 kW R...

Page 6: ...s Abstellen von nicht hitzebest ndigen Gegenst nden auf dem Heizger t oder in dessen N he ist verboten Legen Sie keine W schest cke zum Trocknen auf den Ofen Auch W schest nder oder dgl m ssen in ausr...

Page 7: ...mit dem Kaminofen Problem Grund L sung Glasscheibe verru t zu schnell schlechter Kaminzug Grunds tzlich von Zeit zu Zeit je nach Gebrauch muss jede Glasscheibe mit Austroflamm Glasreiniger gereinigt...

Page 8: ...inal thermal output EN 13240 8 kW 9 kW 10 kW 5 kW 10 kW 6 5 kW Maximum thermal capacity 11 kW 13 kW 14 kW 7 kW 14 kW 9 kW Smallest heating capacity 4 kW 4 5 kW 5 kW 2 5 kW 5 kW 3 5 kW Room heating cap...

Page 9: ...the vicinity of the heating unit is forbidden Do not lay laundry onto the stove for drying Laundry hung up to dry must be kept at a safe distance from the stove because of the danger of fire This wood...

Page 10: ...me to time depending on the frequency of use bad chimney draught contact your chimney sweep elongate chimney draught metering incorrect use of the combustion air supply lever please operate air lever...

Page 11: ...ita fumi 180 mm 180 mm 180 mm 150 mm 180 mm 150 mm Rendimento nominale secondo EN 13240 8 kW 9 kW 10 kW 5 kW 10 kW 6 5 kW Rendimento massimo 11 kW 13 kW 14 kW 7 kW 14 kW 9 kW Rendimento minimo 4 kW 4...

Page 12: ...sulla stufa o nelle sue immediate vicinanze Non mettete ad asciugare biancheria sopra la stufa Stendibiancheria o simili devono essere collocati ad una distanza adeguata dalla stufa pericolo di incen...

Page 13: ...re puliti saltuariamente con un prodotto specifico secondo la frequenza di utilizzo cattivo tiraggio contattate lo spazzacamino di fiducia allungare il tratto di evacuazione fumi uso improprio della p...

Page 14: ...0 kW 6 5 kW Puissance calorifique maximale 11 kW 13 kW 14 kW 7 kW 14 kW 9 kW Puissance calorifique minimale 4 kW 4 5 kW 5 kW 2 5 kW 5 kW 3 5 kW Volume chauff selon l isolation du b timent 98 225 m 114...

Page 15: ...r des objets ne r sistant pas la chaleur sur l appareil ou proximit Ne faites pas s cher de linge sur le po le Les tendages et gouttoirs linge ou autres doivent tre plac s suffisamment loin de l appar...

Page 16: ...ttoyer chaque vitre de temps en temps selon utilisation avec un produit nettoyage vitre Austroflamm Mauvais tirage A v rifier avec l installateur sur lever ventuellement le conduit mesurer le tirage M...

Page 17: ...ass for 6 years and for all stove components made of steel or cast iron a full two years from the date of purchase Steel and cast iron components which show defect in materials or workmanship during t...

Page 18: ...arantie Nous garantissons le fonctionnement irr prochable du corps de l appareil de votre po le AUSTROFLAMM pendant 6 ans toutes les autres pi ces en acier et en fonte tant garanties 2 ans Les pi ces...

Reviews: