ZONEMIX
INSTALLATION AND OPERATION MANUAL
18
SET AUDIO LEVELS
Important: The paging input, chime and messages BYPASS the Zone master volume control. This is to ensure the paging is not too
low or muted if a user turns down the master volume.
1. Select the Zone output you wish to control
2. Select the “Outputs” audio tab in the audio mix section
3. Set the Paging Input, Paging Chime and Message volume controls to the level desired
DISCONNECTING A ZMPS
If a ZMPS needs to be removed from the system, it can be disconnected in the PC control software.
• Go to the appropriate paging station tab.
See the Identify section above if you do not know which station to select.
• Select the “Disconnect” button
• In order to re-connect the ZMPS follow the pairing instructions section of this manual
Note: You can customize the pre-announcement chime of the paging stations. See the SD card section for details
CONNECTING ZMPS PAGING STATIONS CONT.
CUSTOMISE THE PAGING CHIME
The paging chime can be optionally overridden by placing an alternative audio file on the root of a customer suppled SD
card.
• Format: pagingchime.wav
(Only WAV files are supported. Do NOT use MP3 or other audio formats).