ZONEMIX
INSTALLATION AND OPERATION MANUAL
12
PC CONTROL SOFTWARE CONT.
OVERVIEW
The control software consists of three main sections
Section 1
shows 4 zones for the ZONEMIX4 or 8 zones for the ZONEMIX8
• Select the output zone to control
• Set and adjust presets
Section 2
for the currently selected output zone
• Adjust the input channel volume levels, filters, compressor/limiter, crossover (ZONEMIX4 only), tone control and zone master volume
level.
• Apply maximum and minimum volume levels using the “Advanced” tab
Section 2a (accessed by selecting the “outputs” tab)
• Adjust the post zone master volume audio mix for paging, paging chime and message levels.
• Pink Noise and sine waves can also be activated for use during system commissioning
Section 3
• Mic or Line setting for Inputs 1 and 2 and stereo mode (ZONEMIX4 only)
• Apply high pass filters and turn on phantom power
• Apply delay to the output (ZONEMIX4 Only)
• Set output mode - Stereo, Crossover, Mono (ZONEMIX4 Only)
• Set various control options including paging station and wall panel setup, priority levels, scheduling, GPIO and front panel
functions. See below for detailed information