INSTALLATION INSTRUCTIONS
GAS VALVE PRESSURE ADJUSTMENT
The gas valve pressure adjustments must be checked during installation, and if necessary
corrected to suit the gas type available.
“A” represents the main regulator adjusting screw. Access to this screw is obtained by
removing the brass screw cover; use a flat blade screw driver for adjustment of gas
pressure. Note: Gas burner pressure can only be adjusted on high burner setting with both
switches medium and low burner in the “ON” position and flames holding on both burners.
“B” represents the test point for connecting the manometer. Gas Valve is supplied with
brass test tube for connecting the manometer. Note: To obtain reading of gas pressure, open
the brass screw located inside test point with a small blade screw driver, before connecting
the manometer to test point. On completion of checking burner pressure, tighten the brass
screw inside the brass test point.
24
A
B