background image

COMPLETE UNIT WARRANTY 

DESCRIPTION 

 

 

WARRANTY PERIOD   

(FROM DATE OF PURCHASE) 

 

Heat Exchanger 

 

 

5 Years Parts/1 Year Labour 

Main Convection Fan 

 

2 Years Parts/1 Year Labour 

All Other Parts 

 

 

2 Year Parts/1Year Labour 

 

AURORA WARRANTY PROGRAM 

To qualify for the Aurora Warranty Program, you need to fill out the warranty registration form, and have your qualified 
installer  fill  out  the  Installation  Commissioning  Report.  Both  documents  must  be  returned  promptly  to  Aurora  Climate  
Systems. 
Please  note,  that  Aurora  Climate  Systems  will  not  accept  responsibility  for  faults  with  the  appliance  caused  through  
installation  faults.  We  therefore  strongly  recommend  that  you  return  to  Aurora  Climate  Systems  the  Installation  
Commissioning Report and obtain a Certificate of Compliance from your qualified installer for your protection. Failure to 
do so can void your warranty. 
 
It is the policy of Aurora that should a fault develop in the Archer Gas Log Space Heater during its warranty period, Aurora 
will at its own option either fix or repair the appliance in accordance with its present warranty policy. Also the policy of 
Aurora  Climate  Systems  is  if  this  Archer  Gas  Log  Space  Heater  is  found  to  be  defective  in  materials  or  workmanship, 
Aurora  Climate  Systems  will  repair  or  replace  such  defects  in  the  Archer  Gas  Log  Space  Heater  at  Aurora’s  option  in  
accordance with Aurora’s warranty policy. 
 

WARRANTY ON REPLACEMENT PARTS: 

Parts replaced under warranty are warranted for the balance of their original warranty period. 
 

DESIGNATION OF WARANTOR: 

This warranty is extended by Aurora Climate Systems with respect to the Archer Gas Log Space Heater as described here, 
while only in the possession of the original purchaser. 
 

PRODUCT: 

This  Archer  Gas  Log  Space  Heater  is  comprised  of  the  heater  proper  (including  steel  components  and  heat  
exchanger),  fan  assembly,  electronic  components  and  moving  parts.  Except  where  specifically  excluded  from  coverage 
hereunder, this warranty covers all components designated. See Conditions, Exclusions and Qualifications below for further 
information on product coverage. 
 

CONDITIONS, EXCLUSIONS AND QUALIFICATIONS: 

Repair  and  replacement  work  will  be  carried  out  by  the  approved  Service  Agent  of  Aurora  on  the  basis  shown  above,  
subject to proof of purchase and purchase date. Aurora will only accept claims under this warranty in strict accordance with 
the conditions set out below. 

 

1. 

Cost of travelling by service personnel in excess of 25km each way will apply if Aurora’s approved  service agent is 
situated more than 25km from the installation. In such circumstances, Aurora is not obligated to cover any additional 
travel or labour charges incurred by the service agent and such costs will need to be charged to the customer. 

 
2. 

The cost of transporting the  Archer Gas Log Space Heater and parts between the  nearest Aurora dealer or service 
agent and its normal location and where is it necessary for the product to be returned to the manufacturer and then 
returned back to the customer, these costs will be met by the customer. 

 
3. 

The cost of work or a service call where there is no fault with the heater, but where the defective operation or fault in 
the  heater  is  due  to  incorrect  plumbing/  electrical  installation  not  in  accordance  with  Aurora’s  installation  
instructions  and/or  applicable  local  regulations,  or  where  defects  are  caused  by  incorrect  application,  lack  of  
operating knowledge, abuse of the appliance or abuse of the appliance or damage caused by the installer, or other 
persons attempting to install or repair the heater. 

 
4. 

Aurora  expressly  excludes  any  liability  hereunder  for  defects  or  damaged  caused  by  the  

 

installation on or of any components not expressly authorised and approved by Aurora. 

 
5. 

Aurora  further  assumes  no  liability  for  defects  or  damage  caused  by  incorrect  operating  or  performance  of  the  

 

appliance  caused  by  any  modification  or  incorrect  installation.  Unauthorised  components  or  installation  

 

modifications could create a fire hazard by altering the safety design of the Gas Log Space Heater. 

37 

Summary of Contents for Archer IS700

Page 1: ...PN 200110001S Effective January 2009 Serial Number B D Number Model FS706 Model IS700 Model IS760 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE RERERENCE THIS MANUAL COVERS ALL MODELS FROM IS700 IS714 IS...

Page 2: ...creen Installation 26 Insert Surround 27 OPERATING INSTRUCTIONS Automatic Humidifier Operation 28 Operating Instructions Checklist 29 30 Lighting Instructions 31 Fan Operation 32 Shutdown Instructions...

Page 3: ...larification of the instructions contained in this manual please contact Aurora Climate Systems on telephone 03 9795 8895 or facsimile 03 9701 2088 Note As the Archer Gas Log Space Heater you have pur...

Page 4: ...R GAS LOG SPACE HEATER Note If this appliance is installed by a licensed gas fitter who is not familiar on the installation of the heater we recommend that prior to installing the appliance the instal...

Page 5: ...REMOVED FROM THIS APPLIANCE DO NOT ENCLOSE THIS APPLIANCE Aurora Climate Systems A B N 43 108 083 987 71 73 Overseas Drive Noble Park VIC 3174 To be installed by an authorised person in accordance wi...

Page 6: ...Connection Inside 4 3 sided Surround 885 x 742 5 Air Inlet Cover Plate 6 PVC Exhaust Pipe 40mm 7 Flue Exit Point centre line 8 Single Flue Adaptor 9 Single Flexi Flue suit 40mm pipe 11 Bolted Surroun...

Page 7: ...will void the warranty Note On Single Wall flue pipe installations imitation zero clearance fireplace a minimum of 25mm clearance must be provided at the rear of the heater to enable the heater to ge...

Page 8: ...ion 0mm D Height Clearance From Unit 15mm 7 Note The Archer Gas Log Space Heater has been tested and approved for zero clearance to combustible materials Aurora Climate Systems recommends that clearan...

Page 9: ...4 Rear Burner 5 Front Burner NOTE Do not change position of front middle and rear logs as their positions have been preset at the factory Changing log positions will result in faulty gas burner funct...

Page 10: ...r Latches FIG 1 FIG 2 FIG 3 Left Top Door Tab Right Top Door Tab Properly fitted door shown in Fig 1 Undo Latches when removing door shown in Fig 3 Make sure door tabs can be seen through top of heate...

Page 11: ...inspect front and rear burner for particle or dust placement on top of burners If any particles or dust is visible on top of the front and rear burners remove particles before placing logs into posit...

Page 12: ...st the rear at the firebox at the base and at the top B GAS PRESSURE FOR LPG Do not adjust gas burner pressure on LPG Gas burner pressure has been set at factory to required gas burner settings for LP...

Page 13: ...ipe installation if the unit and flue pipe is installed in line with the manufacturer s installation instructions Refer installation diagram for single flue pipe installations Pages 13 16 17 18 19 20...

Page 14: ...HEATER No Description Qty 1 Single Flue Adaptor 1 Supplied with heater 2 40mm PVC Pipe 400mm long 1 Supplied with heater 3 90 PVC Bend 1 Supplied with heater 4 40mm PVC Pipe up to 5 1m Supplied by in...

Page 15: ...pipe for servicing of the heater Note When connecting 40mm pipe at adaptor end and at cowl end ensure that 40mm pipe is long enough to fit in securely at both ends Failure to do so will cause the flam...

Page 16: ...place Note Do not use PVC cement to seal flue pipe connections to allow for removal of flue pipe Incorporate loop in gas connection or use flexible hose for gas connection to allow for removing of app...

Page 17: ...t be able to be removed easily for servicing Not locked in INTERNAL WALL APPLICATION 1 75mm Cowl 2 Flashing 3 BSP Gas Connection Flexible 4 40mm PVC Pipe Zero Clearance 5 45 PVC Elbow 6 45 PVC Elbow 7...

Page 18: ...ROM HEATER Note Total installation length in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends 90 Elbow 65mm PVC cowl to suit 40mm PVC flue pipe External Wall Concrete Slab Internal Wall INSTALLATION...

Page 19: ...in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends Caution To avoid water trap in Flue system 40mm PVC pipe must be supported every 2 metres to avoid PVC pipe sagging and PVC pipe must have fall to...

Page 20: ...lexible Hose Nylaflow G P Hose Code AH50WAS Supplied with Flue Kit SFA002 Note I D Inside Diameter Flange attached to heater s exhaust fan Supplied and fitted to heater Note If adaptor not fitted dril...

Page 21: ...ue pipe being forced downwards Supplied by Installer Gas Cowl Supplied in flue kit For safety install gas cock next to appliance Use 1 2 gas loop or part loop in 1 2 copper pipe to allow unit to be re...

Page 22: ...wo burner switches is called the economy display mode and will only function when a Remote Control Thermostat has been installed in the heater The most common way this button is used is having the Rem...

Page 23: ...ion Please make sure heater is unplugged when installing Remote Control Please Note The front panel must be opened for this wiring to occur The front panel simply pulls forward no tools required NOTE...

Page 24: ...met supplied over gas line and insert into back panel IMPORTANT Note The copper gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from it...

Page 25: ...e Note Gas burner pressure can only be adjusted on high burner setting with both switches medium and low burner in the ON position and flames holding on both burners B represents the test point for co...

Page 26: ...14 WAY RIBBON TO DISPLAY 1 CONV FAN BLUE 2 TR PRIMARY BLACK TR PRIMARY WHITE 8 1 N C 2 3 1 TRANSFORMER 12V AIR PRESSURE SWITCH REAR BURNER SWITCH PIN 5 FRONT BURNER SWITCH TRANSFORMER 240V PIN 18 PIN...

Page 27: ...CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE ALWAYS ENSURE THAT YOUR SAFETY SCREEN SUPPLIED WITH THE HEATER IS FITTED TO THE MAIN FR...

Page 28: ...ater FITTING OF LOUVRE Place the louvre in the surround as shown in Diagram A and fasten with the six screws supplied as shown in Diagram B DIAGRAM B FITTING OF SURROUND Place the surround as shown in...

Page 29: ...utomatic humidifier pump comes on to pump condensate into the stainless steal tray located on the top of the heater the L E D light Page 31 on the front panel will light up and flash for the duration...

Page 30: ...operating incorrectly causing a safety hazard and will void the manufacturer s warranty of the appliance 6 Check and inspect the appliance for gas leaks In the event of gas leaks cut off the gas supp...

Page 31: ...se the appliance not to function correctly 15 Check and verify prior to starting up the appliance that all panels are secured in place and that the main door has been locked in position 16 After verif...

Page 32: ...nd the convection fan will blow warm air from the heater as the heater becomes warmer the medium L E D Item 8 will come on and when the heater has reached its highest operating temperature all three L...

Page 33: ...te It can take up to approximately 20 30 minutes before the fan speed will change and settle on the next setting The firebox temperature and the outside ambient temperature will regulate how quickly t...

Page 34: ...IRING The first fire in your heater is part of the paint curing process Your Archer Gas Log Space Heater has been painted with the highest quality heat resistant silicon paint available in the world T...

Page 35: ...for the heater to do in certain situations Eg Overheating power failure or dips windy conditions pump failure partial or full blockage of flue pipe or no gas All of these operations are monitored by t...

Page 36: ...ced and cleaned annually by a qualified service person to ensure that your appliance is operating efficiently Note If the main convection fan becomes clogged with lint and dust an over temperature sit...

Page 37: ...y Stainless Steel doors can be cleaned with a metal cleaner that can be used on Stainless Steel Please note Stains or imperfections on plated finishes are not covered under warranty Caution Do not use...

Page 38: ...verage hereunder this warranty covers all components designated See Conditions Exclusions and Qualifications below for further information on product coverage CONDITIONS EXCLUSIONS AND QUALIFICATIONS...

Page 39: ...e both ways is to be paid by the owner If Aurora finds a fault with the device they will repair or replace it under the normal warranty terms 1 Year It must also be a recommended device by Aurora Clim...

Page 40: ...11 Sooting up of heater Note For heaters operating on LPG to avoid sooting up of heater LPG bottle must not be run empty For best practice LPG bottles should be refilled after 75 of fuel has been use...

Page 41: ...eceiver must be in the remote position for the learn process to occur The burner switches and the red button must all be in the OFF position You will need some sort of pointy object to press the learn...

Page 42: ...up that you start having difficulty seeing through it this is not normal Nor is having large build up of soot forming on the logs Please note It is normal for some soot to form around the lower and s...

Page 43: ...ously Check Flue system Check Flue system Call Aurora service Front or Rear Burner L E D light item 5 and 6 not flashing when Front or Rear burner switch is engaged Possible fault in Circuit Board Pan...

Page 44: ...eration Front or Rear Burner operating L E D Light item 7 8 9 on Front panel display not coming on for Fan Speed Possible fault in thermistor Call Aurora Service L E D light items 7 8 9 on Front Panel...

Page 45: ...NOTES 44...

Page 46: ...NOTES 45...

Page 47: ...NOTES 46...

Page 48: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING INSTALLATION INSTRUCTIONS TO THE CONSUMER FOR FUTURE REFERENCE DATE OF PURCHASE...