INSTALLATION INSTRUCTIONS
Flexible Flue Kit to suit Fireplace Insert Installations Model IS700
STANDARD FLUE KIT SUPPLIED BY AURORA FOR INSERT INSTALLATION (SFA002)
Note: Standard 75mm Cowl to fit 40mm ø pipe is also supplied with flue kit.
19
40mm N.B. SWV Pipe
(Not Supplied)
40mm N.B. Plain Coupling (Supplied with Flue Kit) (38mm I.D.)
50mm Nylaflow Flexible Hose
Nylaflow G.P. Hose Code AH50WAS
(Supplied with Flue Kit SFA002)
Note: I.D. = Inside Diameter
Flange attached to heater’s
exhaust fan (Supplied and
fitted to heater)
Note: If adaptor not fitted drill
4 holes 3mm ø use mounting
plate as template.
Caution: Only drill holes
through outer casing. Use 4
self-tapping screws 4mm ø x
15mm supplied with assembly.
40mm N.B. x 90º Elbow
38mm I.D. (Supplied with flue kit)
40mm N.B. Barrel Union (Supplied with flue kit)
Archer Inbuilt Heater
60mm S.S. Hose Clamp
150
Note: 150mm clearance required for Flue
Adaptor.