INSTALLATION INSTRUCTIONS
Fireplace Insert Installation Model IS100
-Using Aurora Flexible Flue Kit SFA002 with Single 40mm PVC Flue Pipe using 75mm cowl
20
Note: All flue pipe connections need to be sealed with
PVC cement, except Flue Fan Connection.
Note: Total Installation length in 40mm ø PVC pipe
5100mm with 1 x 90º and 2 x 45º bends.
Fasten 40mm Flue Pipe with
bracket to stop flue pipe
being forced downwards
( Supplied by Installer)
Gas Cowl Supplied
in flue kit
For safety install gas cock
next to appliance
Use 1/2” gas loop or part loop
in 1/2” copper pipe to allow
unit to be removed and
serviced or use flexible gas
hose for gas connection
Aurora flexible flue kit
SFA002
200mm
Galv Sheet Flashing to
seal chimney
(Supplied by Installer)
40mm PVC Pipe
SWV (Supplied by
Installer)
2 x 45º PVC bends
40mm (Supplied by
Installer if required)
5100mm
MAX
Note: Do not allow elbow to sag downwards.
If it does a water trap will develop and
heater will cease to operate.