DIDO LT Installation Manual
19
1.1.7 System
Settings
This menu allows the selection of items which affect the overall DIDO LT operation.
Unit Address
allows many DIDO LT units to be connected via RS-485. When connecting multiple DIDO
LT units via the RS-485, each unit must be addressed differently. This address will be used when
controlling via RS-232 from a control system or PC. In addition, the last unit in the chain must have
RS-485 Termination enable.
The IR remote is also addressable (see IR remote section) and if set to the same address as the DIDO LT,
it will control only that DIDO LT This feature is very useful when multiple DIDO LT units are present to
prevent inadvertently controlling other units.
Remote Query
is a diagnostic tool used to check for any DIDO LT remote’s current address even if it is
not matched to the address of that DIDO LT unit.
OSD Setup
turns on/off the Menu Transparency and OSD.
Menu Transparency
allows the menu to blend with the background.