5.
Packaging
Our products are protected by special packaging for the transport ex works.
The packaging consists of environmentally friendly materials which can
easily be separated and recycled.
For the disposal of the packaging material we recommend recycling and
collection centres.
We use the following packaging materials:
Wooden material boards (OSB)/cardboard/paper/PE film
6.
Fitting the ball handle/manual operation
To avoid damage during transport, the ball handles are fitted to the inside of
the handwheel. Prior to commissioning, the ball handle has to be fitted in
the correct position.
6.1
Fitting the ball handle
.
Remove cap nut.
.
Pull out ball handle and re-insert in
correct position.
.
Fasten with cap nut.
.
Remove sticker from the hand wheel for
fitting the ball handle.
6.2
Manual operation
Manual operation is activated by turning the handwheel. A change-over is
not required. The handwheel does not rotate during motor operation.
Turning the handwheel during motor operation results in
an extension or reduction of the operating time, depending
on the direction of rotation.
7.
Mounting to valve
.
Prior to mounting the part-turn actuator must be checked
for any damage.
.
Damaged parts must be replaced by original spare parts.
.
After mounting to valve, touch up any possible damages
to paint finish.
.
For
butterfly valves
the recommended mounting position is end position
CLOSED.
(Prior to mounting, bring the part-turn actuator to the mechanical end stop
CLOSED by turning the handwheel clockwise).
.
For
ball valves
the recommended mounting position is end position
OPEN. (Prior to mounting, bring the part-turn actuator to the mechanical
end stop OPEN by turning the handwheel counter-clockwise).
.
Thoroughly degrease mounting faces of part-turn actuator and valve.
.
Place coupling sleeve on to valve shaft and secure
(refer to figure A2, detail A or B), ensure that dimensions X, Y and Z are
observed (refer to table 3).
.
Apply non-acidic grease at splines of coupling.
.
Fit actuator so that fixing holes in actuator and valve mounting flange are
in alignment.
If necessary, move actuator up or down one tooth on the coupling.
If required, turn handwheel a little in direction OPEN or CLOSE until holes
align to the threads.
.
Ensure that the spigot (if provided) mates uniformly in the recess and that
the mounting faces are in complete contact.
.
Fasten the actuator with bolts of minimum quality 8.8 using lock washers.
Fasten bolts crosswise to the appropriate torque according to table 3.
8
Part-turn actuators SG 03.3 – SG 04.3
with AUMATIC AC 01.1
Operation instructions
2
1
3
4
Figure A1
Ball handle
Cap nut
MOV
M