760
COMpact 5200/5200R/5500R - Firmware V7.2 - Advanced Information V04 07/2018
Settings – Périphériques
Alarmes
Temps d’attente d’alarme 0..99
Specifies how many seconds elapse before an alarm is repeated, if it has
not been acknowledged.
URL d’action démarrage
The Action URL will be assigned to the alarm type
Démarrage alarme
.
When an alarm is triggered, the Action URL is sent.
Note:
If an alarm delay time was entered, the alarm call via the Action
URL starts after the alarm delay time.
URL d’action confirmation
The Action URL will be assigned to the alarm type
Alarm acknowledged
.
As soon as an alarm subscriber (configured under Devices > Alarms >
Configure > Alarm subscriber (destination number)) acknowlegded the
alarm, the Action URL is sent
Note:
A device that is not recognized by the PBX, cannot acknowlegde
an alarm call by entering the DTMF digit 0.
Action URL timeout
The Action URL will be assigned to the alarm type
Alarm timeout
. If none
of the alarm subscribers acknowledges the alarm, the alarm call ends after
the set alarm loops and the Action URL is sent.