Cabling
2.4.3.1 Grounding the Device
The device must be connected to earth (grounded) using an equipment-earthing conductor.
Protective Earthing
The equipment is classified as Class I according to EN-60950-1 and UL 60950-1 and
must be earthed at all times (using an equipment-earthing conductor).
To ground the device:
1.
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
earthing screw (located on the rear panel), using the supplied washer.
Figure
2-19: Grounding the Device
2.
Connect the other end of the strap to a protective earthing in accordance with the
regulations enforced in the country in which the device is installed.
2.4.3.2 Connecting to Ethernet
To connect the device to the BroadCloud service (WAN-DMZ):
1.
If the device's IP isn't configured yet, connect as shown in Section
If the device's IP
has already been configured:
a.
Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45
port labeled LAN GE port 1.
b.
Connect the other end to the DMZ port assigned by the IT administrator.
Figure
2-20: Connecting the LAN Ports
To connect the device to the enterprise LAN:
2.
If the device's IP isn't configured yet, connect as shown in Section
If the device's IP
has already been configured:
a.
Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45
port labeled LAN GE port 3.