AudioCodes Mediant
2. Installing the Hardware
BroadCloud Hosted UC
17
AudioCodes Mediant CRP
To connect the device to the BroadCloud service (WAN-DMZ):
1.
If the device's IP isn't configured yet, connect as shown in Section
2.
If the device's IP has already been configured:
a.
Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45
port labeled LAN GE port 1.
b.
Connect the other end to the DMZ port assigned by the IT administrator.
Figure
2-15: Connecting the LAN Ports
To connect the device to the enterprise LAN:
1.
If the device's IP isn't configured yet, connect as shown in Section
2.
If the device's IP has already been configured:
a.
Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45
port labeled LAN GE port 3.
b.
Connect the other end to your local network LAN layer 2 switch port. This port will
be used to communicate with the IP-Phones and/or ATA Devices.
2.3.5
Powering up
The device receives power from a standard alternating current (AC) electrical outlet. The
connection is made using the supplied AC power cord.
Table
2-11: Power Specifications
Physical Specification
Value
Input Voltage
Single universal AC power supply 100 to 240V
AC Input Frequency
50 to 60 Hz
AC Input Current
1.5A
Warning:
•
The device must be connected to a socket-outlet providing protective earthing.
•
Use only the AC power cord that is supplied with the device.
Summary of Contents for Mediant 2600
Page 2: ......