40
DW5066 All-in-one wall panel
Functions
The DW5066 is the advanced All-in-one wall panel for the R2. This wall panel has a
graphic display and can control the routing, volume, bass, treble and mute for multiple
zones (up to 8) on one R2. Besides those control functions, it also provides the possibility
to connect a microphone and a stereo line input source. The DW5066 wall panel should
be connected to the R2 by means of a UTP/FTP Cat6 (or better) cable. First read the PI
connection principles in the beginning of this chapter before making any connections.
The following functions of multiple zones of the R2 can be controlled:
- Volume within a range of 0dB to -70 dB
- All inputs can be selected
- Mute can be activated
- Bass within a range from -9dB to +9dB
- Treble within a range from -9dB to +9dB
Configuration
Before the DW5066 can operate, the configurations should be made. First of all, an
address need to be assigned and the available inputs need to be defined.
Follow these steps to configure:
1) Go to the “Setup” menu and click “System configuration”. Now you have the possibility
to choose between “Paging”, “DW5066” and “DW3020/4020”. To configure the settings
for the DW5066 wall panels, click the corresponding button. Now a window is displayed
which provides all the configuration possibilities for the DW5066. On the left side, a
dropdown list is displayed whereby the address for the DW5066 can be selected. The
address can be selected between “W001” and “W008”. Logically, you start with address
“W001” for the first wall panel, and increases for every additional wall panel. After the
desired address is selected, click the “Set address” button. After this button is pressed,
the DW5066 will start blinking. To confirm the selected address with the wall panel,
click the big rotary button on the front of the wall panel. When this button is pressed, the
address will be assigned to the selected wall panel.
NOTE
It is recommended that when assigning the DW5066 an address the number matches
the socket location on the back side of the R2. In this was W001 will also represent
RS485(1)
2) The zones which you want to control with the selected wall panel can be selected by
means of the “Controlled zones” dropdown list. When selecting a zone in this dropdown
list, the zone name will appear in the listbox below. The zones can be removed again from
this listbox by selecting them, and clicking the “Remove Zone” button.
3) The inputs which are selectable with the selected wall panel can be selected by means
of the “Selectable inputs” dropdown list. All inputs which available on the R2 can be
selected in this dropdown list, such as the direct line inputs, the peripheral inputs, the
fiber inputs, the priority inputs and the integrated DSP signals. When selecting an input
signal in this list, the signal name will appear in listbox below. The input signals can
Summary of Contents for R2
Page 1: ...R2 User Manual www audac eu ...
Page 2: ...2 ...
Page 8: ...8 ...
Page 58: ...58 Notes ...
Page 59: ...59 Notes ...
Page 60: ...60 Notes ...