CHAPTER 9: MAINTENANCE TAB
DigiVu
®
Series Multichannel MPEG-2/H.264 Encoder/Multiplexer with QAM &/or IP Output - Installation & Operation Manual
9-3
•
“Channel 4 Video Status”
•
“Channel 5 Video Status”
•
“Channel 6 Video Status”
•
“Channel 7 Video Status”
•
“Channel 8 Video Status”
•
“Channel 9 Video Status”
•
“Channel 10 Video Status”
9.4.2 Traps Reported by SNMP
•
Temperature beyond Threshold (MAJOR)
•
Fan Failure (MAJOR)
•
Video Status changed channel 1 (MAJOR)
•
Video Status changed channel 2 (MAJOR)
•
Video Status changed channel 3 (MAJOR)
•
Video Status changed channel 4 (MAJOR)
•
Video Status changed channel 5 (MAJOR)
•
Video Status changed channel 6 (MAJOR)
•
Video Status changed channel 7 (MAJOR)
•
Video Status changed channel 8 (MAJOR)
•
Video Status changed channel 9 (MAJOR)
•
Video Status changed channel 10 (MAJOR)
SNMP Server:
This is the IP address of the remote Management Console which is the computer that will receive traps sent by the DigiVu and
is the computer with SNMP software installed. This is the system which will receive the SNMP traps. Only one SNMP manager
may be specified.
9.4.3 SNMP Port:
By default, the DigiVu assigns port 161 for sending and receiving requests. This is the default and commonly used port for
SNMP messaging. SNMP uses UDP (User Datagram Protocol).
9.4.4 SNMP MIB
If you want to implement SNMP monitoring you will need the SNMP MIB. Get this by requesting it from ATX Networks technical
support at the numbers listed in
“Contact ATX Networks” on page 15-1.
9.5 Remote Update Server:
Feature not currently implemented.
Remote Server Port:
Feature not currently implemented.
Schedule Remote Update:
Feature not currently implemented.
Schedule Day:
Feature not currently implemented.
Schedule Hour:
Feature not currently implemented.
9.6 Platform Control Buttons
9.6.1 Force Update
Feature not currently implemented.
9.6.2 Go to Sleep
This control causes the DigiVu to go into a low power mode which reduces the internal temperature buildup.
NOTE:
This is a service affecting operation.
9.6.3 Board Time
This control allows the real time clock to be set so that time stamps on the logs reflect real time. This only needs to be set once
as the backup battery installed in the DigiVu equipment will keep the clock running during any power outages. The battery may
Figure 9-5:
Remote Update Server
Figure 9-6:
Maintenance Control Buttons