PERATION

 

Your DPX16 has seven mode control buttons and sixteen numbered “camera” buttons which allow easy
access to all modes of operation. The seven mode buttons on the left are used to control monitor display
operations and VCR playback.  An LED below each button will light when the unit is in the mode
corresponding to that button.  Note that live camera display modes do not affect multiplex recording.
Following is a summary of each button’s function and the DPX16 operating modes.

DISPLAY
This button cycles the monitor display through the 4X4, 3x3, and quad displays in live or VCR playback
modes.  In addition, it will return the unit to the 4x4 display mode from any other display mode. Successive
button pushes change the display operation from 4X4, to 3x3, to quad, then back to 4x4, and so forth.  A
push and hold of this button for approximately 3 seconds will bring up the DPX16 set up main menu.  To
view additional cameras in the 3x3 or quad display modes, push the SEQUENCE button and the DPX16
will sequence the display through the available cameras.  You can stop on any set of cameras by pushing
the SEQUENCE button again to stop SEQUENCING.

FREEZE
In all display modes (except Zoom), a press on this button will freeze the camera image(s) on the monitor
display (the multiplex output to the VCR recording is still live during all display modes).  Another push of
this button will deactivate the “freeze” mode.  A push and hold of this button for approximately 3 seconds
will put the DPX16 front panel into Call Monitor control mode (see “Call Monitor Operation” on page 8).
This button is also used to pan “left” in Zoom mode.

SEQUENCE
A button press will activate the camera sequencing for the present mode (except Zoom) and another push
of this button will deactivate the “sequencing” mode.  The default camera hold time is 3 seconds.  A button
press during “VCR Playback” mode will cause a multicamera display to switch to the next set of cameras.
This button is also used to pan “right” in Zoom mode.

PIP
When starting in the 4x4, 3x3, quad, or full screen camera display in live display or VCR playback modes,
pressing the PIP (Picture-in-Picture) button will cause the unit to switch to the "Single PIP" display.
Additional presses will cycle the unit through "Dual PIP", “Split Screen”, “Squish Screen”, "Full Frame" and
back to "Single PIP" displays.  How cameras will appear in these displays is programmable (See “Display
Sequence Set Up” on page 13)
.  This button is also used to pan “up” in Zoom mode.

QUADRANT
This button rotates the orientation of the cameras clockwise on the screen into the desired positions in
“PIP”, “Dual PIP”, “Split Screen”, and “Squish Screen” display modes.  This button is also used to pan
“down” in Zoom mode.

ZOOM
The ZOOM function will expand the selected portion of a full frame camera image.  A button press will
cause a box to appear on the screen that indicates the image area that will be expanded.  Successive
button presses will increase the magnification factor from 2X to 3X, 4X, and 5X.

VCR
Pressing this button will switch monitor display from the live camera display mode to the VCR playback
mode. The LED indicator will light to show that VCR playback is now possible.  The display will initially be
in 4x4 mode and the monitor screen will show the message “VCR Playback”. To see non-multiplexer
images (VCR setup menus for example) or to troubleshoot VCR tracking or other problems, the “VCR
Bypass” function is used.  See the following page for a description of the “VCR Bypass” function.  When
the DPX16 is in Zoom mode, this button will cause the image to “zoom out” to the next lower magnification
factor and eventually back to full screen.

Summary of Contents for DPX16

Page 1: ...Owner s Manual and Operating Instructions Instructions for basic operation and installation Printing Revision 5 Version 2 0...

Page 2: ...G Camera Recording Priority 11 Camera Monitor Disable 12 Activity Detection Set Up 12 Display Sequence Set Up 13 Dwell Adjustment 13 Display Sequencing Format 13 Sequencing Format Screens 13 Alarm Set...

Page 3: ...ecording speed record hours mode Proper VCR playback operation requires that the DPX16 be set up to multiplex at the rate which is compatible with your VCR recording speed see page 10 During multiplex...

Page 4: ...grammable external Master Enable signal The DPX16 has sixteen alarm channels associated with the sixteen camera inputs Each alarm channel includes a programmable external input video Activity Alarm an...

Page 5: ...DPX16 as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections and switch settings for your particular installation Power up...

Page 6: ...ideo connector to the video input of the VCR You must use either the Composite video connection BNC or the S Video DIN connection In order for your DPX16 to work properly with the VCR DO NOT CONNECT C...

Page 7: ...for the present mode except Zoom and another push of this button will deactivate the sequencing mode The default camera hold time is 3 seconds A button press during VCR Playback mode will cause a mul...

Page 8: ...utton for selecting cameras and successive button presses will rotate through the available cameras Sequencing is initiated by pressing and holding the remote control s FREEZE button for approximately...

Page 9: ...sages Time Date Setting Time and date for the on screen calendar and clock is set from this menu Selecting 1 Edits the hour of the day In 24 hour mode 0 through 23 is accepted as entered 2 Edits the m...

Page 10: ...e video format and playback discriminator functions See the Advanced VCR options menu on page 20 VCR Selection Selecting 1 9 Selects a particular VCR from the displayed list The first two entries are...

Page 11: ...e a limited set of front panel buttons the PIP button is used to input characters Using the legend any character can be entered in the present character location The VCR button is used to move to the...

Page 12: ...Only The No Video indication will be given on the live display along with the blue background if the camera s signal is not present Activity Detection Set Up This menu is used to access and program A...

Page 13: ...the display sequence format to suit your application You can program a specific selection of cameras for sequencing Selecting 1 Enters edit mode for dwell time see above 2 Enters Full Camera Call Up f...

Page 14: ...ence 1 Cameras 12345678910111213141516 Enter Cameras you want displayed in the sequence Camera Select DISPLAY Accept and Return PIP Display Sequence 1 Background As is 2 Insert 12345678910111213141516...

Page 15: ...camera s will be displayed and the alarming camera s will have an increased multiplexing rate When an alarm is disabled Off an alarm input will not affect any aspect of the VCR multiplexing the live c...

Page 16: ...d return the display to the non edit mode as shown Note that the setting of the hours format in the Time and Date menu will determine the hours display in this menu Also note that when the system is i...

Page 17: ...is the amount of time that the alarm event will be held so that the alarm camera image can be kept on the display screen and mutiplexed at a high frame rate to the VCR The maximum time for holding an...

Page 18: ...camera number and type of alarm for each alarm event that has been stored The Alarm Log can store up to 100 alarm events at which point new alarm events continue to be stored and replace the oldest e...

Page 19: ...e DISPLAY button until the ATV name appears This is not the preferred method of bypassing security since this step also returns all internal parameters and options to their factory defaults The securi...

Page 20: ...same for record and playback Camera Switch Input For most applications the VCR delay table setting will provide the simplest setup and operation for multiplex recording For advanced applications such...

Page 21: ...your remote control does not appear to work for any reason please perform the following steps before contacting the factory To program the remote control to work with the DPX16 1 Ensure that batteries...

Page 22: ...performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is a list of pairs of num...

Page 23: ...om delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 5 Select Edit Delay Table option 1 and the menu shown here will appear Note that before yo...

Page 24: ...o the limitations introduced by these current limiting resistors The alarm connectors on the DPX16 are DB 15 15 pin connectors For ease of installation a breakout adapter is provided with the 16th ter...

Page 25: ...m on pin 9 must not exceed 30 Vdc and the closed circuit current alarm active into pin 9 must be less than 50 mA The breakout adapter board is numbered compatibly with the DB 15 connector so the follo...

Page 26: ...ton Lock n 0 sets front panel button lock OFF and n 1 sets button lock ON CM Call Monitor will cause the DPX16 to toggle between Normal and Call Monitor modes When in Call Monitor mode button commands...

Page 27: ...000 Sony SVT 3050 Sony SVT L200 Sony SVT L400 Sony SVT S3100 Sony SVT 5050 short long Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short l...

Page 28: ...0 NTSC 720 X 576 PAL 4 2 2 256 Gray Levels 16 Million Colors Refresh Rate 30 Frames Per Second NTSC 25 Frames Per Second PAL Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and...

Page 29: ...ar where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functional...