background image

 DPX16:  Instructions for Basic Operation and Installation

Page 18

Alarm Activation Type
Selecting:

1 - 16

Toggles the selected camera between
“Contact Closure”, “Contact Open”, “Logic
Low”, or “Logic High” triggering the alarm.

In many applications the switch contact connection is
between the alarm input pin and the chassis or signal
ground.  In the DPX16 the contact connection can be
between either the ground (alarm connector pin 15) or
the +5V (alarm connector pin 13). In some alarming
devices this is not a metallic switch contact but rather
a solid state device which “grounds” (Logic Low) the
input as a normal condition or as an alarm condition.
The four activation modes are provided to simplify
connection to most alarm sources.  See “Alarm
Interconnection on the DPX16” on page 24.  T
he
default Alarm Activation Type is “Contact Closure”.

The DPX16 alarm activation is defined as follows:

Contact Closure:

The alarm pin is connected to a current source (5V or ground).

Contact Open:

The alarm pin is not connected to any current source (unconnected pin).

Logic Low:  

A logic “low” level less than 0.8V (ground) is present at the alarm pin.

Logic High:

A logic “high” level greater than 2.4V (+5V) is present at the alarm pin.

Alarm Log

The Alarm Log menu is used to view the current
contents of the internal Alarm Log and to clear the log
or transmit the log contents to the serial port for
printing.  The Alarm Log contains the time, date,
camera number, and type of alarm for each alarm event
that has been stored.  The Alarm Log can store up to
100 alarm events at which point new alarm events
continue to be stored and replace the oldest event in
the buffer.  An “Overflow” message is displayed in the
upper left corner of the Alarm Log menu if more than
100 events have occurred indicating older alarm events
have been displaced.  An alarm event is generated
when any enabled and valid scheduled External,
Activity, or Video Loss alarm occurs (See “Alarm
Scheduling”
 on
page 15).  The Alarm Log is a very useful tool for
reviewing the VCR recording allowing rapid location and
review of recorded video time periods of interest.

The Alarm Log may be printed on a serial interface
printer which is connected to the DPX16 Serial Port. The log may also be sent to a host computer for
storage or processing rather than a printer.

The Alarm Log can be cleared by pressing the ZOOM button.

          Set Alarm Activation Type

 1: Contact Closure   9: Contact Closure
 2: Logic Low           10: Contact Closure
 3: Logic High          11: Contact Closure
 4: Contact Open     12: Contact Closure
 5: Contact Closure 13: Contact Closure
 6: Contact Closure 14: Contact Closure
 7: Contact Closure 15: Contact Closure
 8: Contact Closure 16: Contact Closure
 Camera: Select
 DISPLAY: Accept and Return

Alarm Log

Page 1/5

 Time             Date           Cam    Type
 09:49:27AM  15AUG97   1         VidLoss
 10:40:28AM  16AUG97   2         Act
 11:49:27PM  16AUG97   16       Ext
 11:52:00AM  16AUG97   11       Act
 12:02:57AM  16AUG97   10       Act
 01:20:15AM  16AUG97   16       Ext
 06:01:37AM  16AUG97   16       Ext
 06:02:15AM  16AUG97   11       Act

 Up Arrow:     Next       VCR: Print Log
 Down Arrow: Prev     Zoom: Clear Log
 DISPLAY: Return

Summary of Contents for DPX16

Page 1: ...Owner s Manual and Operating Instructions Instructions for basic operation and installation Printing Revision 5 Version 2 0...

Page 2: ...G Camera Recording Priority 11 Camera Monitor Disable 12 Activity Detection Set Up 12 Display Sequence Set Up 13 Dwell Adjustment 13 Display Sequencing Format 13 Sequencing Format Screens 13 Alarm Set...

Page 3: ...ecording speed record hours mode Proper VCR playback operation requires that the DPX16 be set up to multiplex at the rate which is compatible with your VCR recording speed see page 10 During multiplex...

Page 4: ...grammable external Master Enable signal The DPX16 has sixteen alarm channels associated with the sixteen camera inputs Each alarm channel includes a programmable external input video Activity Alarm an...

Page 5: ...DPX16 as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections and switch settings for your particular installation Power up...

Page 6: ...ideo connector to the video input of the VCR You must use either the Composite video connection BNC or the S Video DIN connection In order for your DPX16 to work properly with the VCR DO NOT CONNECT C...

Page 7: ...for the present mode except Zoom and another push of this button will deactivate the sequencing mode The default camera hold time is 3 seconds A button press during VCR Playback mode will cause a mul...

Page 8: ...utton for selecting cameras and successive button presses will rotate through the available cameras Sequencing is initiated by pressing and holding the remote control s FREEZE button for approximately...

Page 9: ...sages Time Date Setting Time and date for the on screen calendar and clock is set from this menu Selecting 1 Edits the hour of the day In 24 hour mode 0 through 23 is accepted as entered 2 Edits the m...

Page 10: ...e video format and playback discriminator functions See the Advanced VCR options menu on page 20 VCR Selection Selecting 1 9 Selects a particular VCR from the displayed list The first two entries are...

Page 11: ...e a limited set of front panel buttons the PIP button is used to input characters Using the legend any character can be entered in the present character location The VCR button is used to move to the...

Page 12: ...Only The No Video indication will be given on the live display along with the blue background if the camera s signal is not present Activity Detection Set Up This menu is used to access and program A...

Page 13: ...the display sequence format to suit your application You can program a specific selection of cameras for sequencing Selecting 1 Enters edit mode for dwell time see above 2 Enters Full Camera Call Up f...

Page 14: ...ence 1 Cameras 12345678910111213141516 Enter Cameras you want displayed in the sequence Camera Select DISPLAY Accept and Return PIP Display Sequence 1 Background As is 2 Insert 12345678910111213141516...

Page 15: ...camera s will be displayed and the alarming camera s will have an increased multiplexing rate When an alarm is disabled Off an alarm input will not affect any aspect of the VCR multiplexing the live c...

Page 16: ...d return the display to the non edit mode as shown Note that the setting of the hours format in the Time and Date menu will determine the hours display in this menu Also note that when the system is i...

Page 17: ...is the amount of time that the alarm event will be held so that the alarm camera image can be kept on the display screen and mutiplexed at a high frame rate to the VCR The maximum time for holding an...

Page 18: ...camera number and type of alarm for each alarm event that has been stored The Alarm Log can store up to 100 alarm events at which point new alarm events continue to be stored and replace the oldest e...

Page 19: ...e DISPLAY button until the ATV name appears This is not the preferred method of bypassing security since this step also returns all internal parameters and options to their factory defaults The securi...

Page 20: ...same for record and playback Camera Switch Input For most applications the VCR delay table setting will provide the simplest setup and operation for multiplex recording For advanced applications such...

Page 21: ...your remote control does not appear to work for any reason please perform the following steps before contacting the factory To program the remote control to work with the DPX16 1 Ensure that batteries...

Page 22: ...performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is a list of pairs of num...

Page 23: ...om delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 5 Select Edit Delay Table option 1 and the menu shown here will appear Note that before yo...

Page 24: ...o the limitations introduced by these current limiting resistors The alarm connectors on the DPX16 are DB 15 15 pin connectors For ease of installation a breakout adapter is provided with the 16th ter...

Page 25: ...m on pin 9 must not exceed 30 Vdc and the closed circuit current alarm active into pin 9 must be less than 50 mA The breakout adapter board is numbered compatibly with the DB 15 connector so the follo...

Page 26: ...ton Lock n 0 sets front panel button lock OFF and n 1 sets button lock ON CM Call Monitor will cause the DPX16 to toggle between Normal and Call Monitor modes When in Call Monitor mode button commands...

Page 27: ...000 Sony SVT 3050 Sony SVT L200 Sony SVT L400 Sony SVT S3100 Sony SVT 5050 short long Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short l...

Page 28: ...0 NTSC 720 X 576 PAL 4 2 2 256 Gray Levels 16 Million Colors Refresh Rate 30 Frames Per Second NTSC 25 Frames Per Second PAL Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and...

Page 29: ...ar where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functional...

Reviews: