Installation
31
Apex-10 / Apex-10H
7.6
Installation Of Column Extension (Ref. Fig. 9)
• Remove the column extension from
the package. Make sure to be careful
to avoid damaging the paint;
• Align the holes between the column
and the extension with carriage bolts
M10X20 and fl ange nuts M10;
• Tighten the bolts and nuts thoroughly.
7.7 Anchoring
Columns
• Use the base plate on the column as a
guide and drill each hole in the
concrete with the rotary hammer drill 3/4in bit. Please refer to the anchor
bolt manufacture website for recommended values. To assure full holding
power, do not ream the hole or allow drill to wobble;
• After drilling, remove dust thoroughly from each hole using compressed air
and/or wire brush. Make certain that the column remains aligned with the
chalk line during this process;
• Assemble the
washers and nuts
on the anchors then
tap into each hole
with a hammer
until the washer
rests against the
base plate. Be sure
that if shimming
is required that
enough threads are
left exposed;
• If shimming is
required, insert the
shims as necessary
under the base
plate so that when
the anchor bolts
are tightened, the
columns will be
plumb;
Figure 10
Figure 9
Summary of Contents for APEX-10
Page 1: ......
Page 19: ...Technical Specification 19 Apex 10 Apex 10H Figure 3a Standard Version...
Page 20: ...Technical Specification 20 Apex 10 Apex 10H Figure 3b Taller Version...
Page 23: ...Technical Specification 23 Apex 10 Apex 10H Figure 6 Electrical Diagram 220V 60Hz 1PH...
Page 26: ...Safety 26 Apex 10 Apex 10H...
Page 27: ...Safety 27 Apex 10 Apex 10H...
Page 30: ...Installation 30 Apex 10 Apex 10H Figure 8a Floor Plan...
Page 61: ...Parts Catalogue 61 Apex 10 Apex 10H Parts Catalogue ED 01 2015...