Installation
39
Apex-10 / Apex-10H
7.14 Make The Electrical Connection
The electrical hookup work must be carried out by a qualifi ed
electrician.
Make sure that the power supply is correct.
Make sure the phase connection is correct. Improper electrical
hookup can damage the electric motor. This will automatically
void warranty.
Make sure the lift is well grounded.
The power unit must be kept dry. NOT FOR OUTDOOR USE
Do not use a 60Hz motor on a 50Hz power supply.
• Make the electric hookup to the hydraulic power unit referring to the wiring
diagram (fi g. 6) using the included electric cable;
• When routing the electric
cable for the overhead
switch, make sure to
keep it clear of any
moving parts and route
it through the hose
clamps on the power-side
column;
• Make sure to install
a circuit breaker on
the circuit: 40A for
220V/60Hz/1Ph.
Figure 26