ATLAS North America Proprietary
Sea Scan ARC Scout MKII Operations Manual
1 of 1
Page: 14
Issue: 1.2.4
SCTM2-OPS
Operations Manual
16. The Scout MkII now is ready to go. Use the Sonar Control web page to control the Sonar. See section 5
for more information on the Web Interface.
4
Communications
The Scout MkII system's communications can be broken up into the following categories:
1. HTTP Server (Web Interface) - used for control and configuration
2. TCP Console - used for NMEA Data input and Console Commands - available on TCP or RS-232
3. SDS Data Output - available on UDP only
Below is a list of the Scout MkII's networks connections with protocol type and associated port number.
Connection Name
Protocol
Port Number
Description
HTTP Server
TCP/IP
80
Web server.
TCP Console
TCP/IP
23
Dual purpose console and
NMEA0183 data over TCP
interface. Operates similar to
a telnet connection.
SDS Over UDP
UDP/IP
1409
SDS Data Output
Note:
A maximum of 3 network ports can be used simultaneously.