Atlantic Ultraviolet Sanitron S17A Owner'S Manual Download Page 9

9

r

eCommenDeD

 o

Ptions

1. 

GUARDIAN

 

Ultraviolet Monitor*:

 Visually indicates the level of germicidal ultraviolet energy that penetrates the quartz 

sleeve and the water within the water purifier. The ultraviolet monitor is capable of operating an optional 

Promate

™ 

Audio 

Alarm and/or 

Promate

™ 

Solenoid Valve. The ultraviolet monitor will detect reduction of ultraviolet levels due to:

•  Fouling or deposits on the quartz sleeve.
•  Poor ultraviolet transmission through the water; color, turbidity, and organic or other impurities in the water can reduce or 

interfere with the transmission of ultraviolet rays.

•  Lamp outage or component failure. (Monitor will not function in power outage.)
•  Depreciation of the lamp output due to usage or other cause. Lamp output gradually depreciates with use. Lamp 

replacement is recommended once each year.

2. 

SENTRY

 Safety Sensor:

 Indicators provide constant visual monitoring of normal operation. In the event of ballast or lamp 

failure the safety sensor indicates an alarm condition. The safety sensor is capable of operating an optional 

Promate

™ 

Audio 

Alarm and/or 

Promate

™ 

Solenoid Valve.

3. 

STERALERT

™ 

Lamp Status Alarm:

 Produces a high pitched, pulsed tone when the water purifier is no longer 

functioning when visible light fails.

4. 

SureFLO

 Flow Control Valve*:

 Limits water flow to the rated capacity of the purifier. The flow control valve is located 

in line prior to the water purifier, and should be protected from ultraviolet exposure by the use of a 90-degree elbow fitting 

between the flow control valve and the water purifier.

5. 

Promate

™ 

Audio Alarm*:

 Activated by the Ultraviolet Monitor or Safety Sensor, alerts the user to any malfunction detected.

6. 

Promate

 

Solenoid Valve*:

 Operated in conjunction with the Ultraviolet Monitor, Safety Sensor or Time Delay 

Mechanism, this valve prevents water flow through the water purifier when an abnormal condition is detected or in 

the event of power failure.

7. 

Promate

 

Elapsed Time Indicator:

 A non-resettable display of the water purifier operating hours. Useful for scheduling and 

recording maintenance and lamp replacement.

8. 

Promate

 

Time Delay Mechanism*:

 Provides a 2-minute warm up period during which the ultraviolet lamp achieves its 

full germicidal output before the water is allowed to flow through the water purifier. The time delay mechanism is used in 

conjunction with, and is electrically connected to the Solenoid Valve.

9. 

Promate

 

Wall Mount Kit:

 Stainless steel wall brackets provide quick and easy installation and professional finish. 

Pre-drilled and ready to install. Optimizes free air circulation to cool ballast housing.

10. 

QUANTUM

 Thermal Optimizer:

 Thermal relief valve used to help regulate the water temperature inside the water 

purifier’s disinfection chamber. Since the ultraviolet output of a germicidal lamp is affected by temperature it is important to 

keep the lamp’s temperature within the peak output temperature range.

11. 

Promate

 

Safety Glasses: 

Safety eyewear should be used as general-purpose safety protection and for additional shielding 

from ultraviolet rays

12. 

Promate

 

Face Shield: 

Adjustable headgear and lightweight visor provides eye and face protection from germicidal 

ultraviolet rays.

* Use of this option is recommended by U.S. Public Health Service “Criteria for Acceptability of an Ultraviolet Disinfection Unit.” 

Originally issued April, 1966.

NOTE: The recommended options above are available from Atlantic Ultraviolet Corporation

®

 or a distributor of their 

products. For the other devices that may be required for your application, please contact your local water treatment dealer, 

plumber or plumbing supplier.

Summary of Contents for Sanitron S17A

Page 1: ...d Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Models S37C and S50C Installation Oper...

Page 2: ...ns when packaging equipment to prevent damage Care fully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 3: ...out proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the wat...

Page 4: ...cidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the q...

Page 5: ...a where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it...

Page 6: ...or with the optional wall mounting kit The purifier should not be solely supported by its plumbing connections 4 The water purifier must be connected to the cold water line only Inlet water temperatu...

Page 7: ...r Figure 4 NOTE Be sure to keep the large O Ring on the chamber head when removing this from the chamber 4 Remove PVC pipe and discard REMINDER be sure that the Teflon washer and O Ring from both ends...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve Figure 4 Initial Installation of Quartz Sleeve TELFON WIPER SEGMENTS GLAND FITTING QUARTZ SLEEVE WIPER ROD ASSEMBLY CHAMBER HEAD LARGE RUBBER O RING...

Page 9: ...in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of p...

Page 10: ...culty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency o...

Page 11: ...lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Reinstall lamp in reverse order Germicidal ultraviolet...

Page 12: ...is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push...

Page 13: ...static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end...

Page 14: ...ep ballast housing and mounting hardware in a clean dry area 2 Carefully remove as much of the broken quartz sleeve as possible from each end of the chamber 3 Remove chamber head clamp by using a 7 16...

Page 15: ...g located in the center of the disinfection chamber and protrudes into the chamber 1 Disconnect power to water purifier 2 Shut off water supply to the water purifier via the inlet and outlet shut off...

Page 16: ...tenance section Quartz sleeve sealing O Ring s worn damaged Shut down purifier drain and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance...

Page 17: ...dio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional Optional Optional Elapsed Time Indicator Optional Optional Optio...

Page 18: ...18 REPLACEMENT PARTS SANITRON Models S17A S23A Figure 11 Exploded View S17A S23A...

Page 19: ...15 Chamber 1 25 1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 151...

Page 20: ...20 SANITRON Models S37C S50C Figure 12 Exploded View S37C S50C...

Page 21: ...acer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...lamps and Other parts One 1 year Limited Warranty from the date of original purchase Within the warranty period we shall repair or replace such products which are returned to us with shipping charges...

Reviews: