Atlantic Ultraviolet Sanitron S17A Owner'S Manual Download Page 24

24

USER ASSISTANCE

Atlantic Ultraviolet Corporation

®

 

makes every effort to ensure that the 

SANITRON

®

 Ultraviolet Water Purifiers 

are products of superior quality and 

workmanship. This manual describes the 

installation, operation and maintenance 

of the 

SANITRON

®

 Ultraviolet 

Water Purifiers

.

Please read and become familiar with the 

contents of this manual before installing 

or using this purifier. If after reading 

the manual you still have questions, or 

concerns, regarding the installation or 

use of this purifier, contact our offices, 

weekdays between 8:30 am and 5:00 pm 

Eastern Time, at:

Atlantic Ultraviolet Corporation

®

375 Marcus Boulevard

Hauppauge, New York, 11788
Tel: 631.273.0500

Fax: 631.273.0771
Email: [email protected]

Website: Ultraviolet.com

 BuyUltraviolet.com

P

atent

 n

otiCe

No attempt has been made to determine the patent status of applications illustrated or described in this publication. Inclusion in this 

publication of any design or method of use, which may be patented, is not to be construed as promoting or sanctioning unauthorized use.

nsf/ansi

NSF/ANSI 61 is a set of national standards that relates to water treatment and establishes stringent requirements for the control of 

equipment that comes in contact with either potable water or products that support the production of potable water. NSF/ANSI 372 was 

set in 2011 to establish procedures to meet the 0.25% lead content requirement of the RLDWA (Reduction of Lead in Drinking Water 

Act) using a wetted surface area average calculation or just simply using all no-lead materials for areas in contact with drinking water. 

NSF/ANSI 372 includes a broader scope of drinking water products covered by the law which may not be covered under NSF/ANSI 61 

and enables large or complex products and assemblies to achieve certification.

WARRANTY & PRODUCT REGISTRATION 

We warrant this product to the original owner to be free from defects in material and workmanship when installed in 

accordance with Atlantic Ultraviolet Corporation

®

 specifications for a period of time as follows:

UV Water Purifier Chambers

 – Type 316 stainless steel chambers will have a Twelve (12) year Limited Warranty on the stainless 

steel chamber, from the date of original purchase while the Type 304 stainless steel chambers will have a Six (6) year Limited 

Warranty on the stainless steel chamber.

UV Air Disinfection Housing

 – Three (3) year Limited Warranty on the metal housing, from the date of original purchase.

Ballast

 – Three (3) year Limited Warranty, from the date of original purchase.

UV lamps and Other parts

 – One (1) year Limited Warranty from the date of original purchase.

Within the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid and which 

are determined by us to be defective. This warranty will not apply to any product, which has been subjected to misuse, negligence or 

accident; or misapplied; or modified; or repaired by unauthorized person; or improperly installed. Warranty will be null and void if 

any of the product’s original labels are removed. This Limited warranty excludes the cost of labor.
The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of claims, including claims 

of breach of warranty, within thirty (30) days after the Buyer discovers or should have discovered the facts upon which the claim is 

based. Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim.
The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or implied, 

including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described 

herein. We further disclaim any responsibility whatsoever to the customer, or to any person for injury to person, damage to, or loss 

of property or value caused by any product which has been subjected to misuse, negligence, accident; or modified or repaired by 

unauthorized persons; or improperly installed.
Under no circumstances shall the Company be liable for any incidental, consequential or special damages; losses or expenses arising 

from the contract for this product, or in connection with the use of, or inability to use, our product for any purpose whatsoever.
Be sure to register your product and validate purchase within 30 days — registration is simple and will take less than 2 minutes to do. 

NOTE – failure to register your purchase may jeopardize warranty.

Go to Ultraviolet.com and scroll down to the bottom of the page, under “Trust” click the “Warranty Registration Form”, complete and 

click “Submit”. Or click on “Warranty Registration PDF” to download the warranty registration card as a PDF, complete and mail to 

us at 375 Marcus Boulevard, Hauppauge, NY 11788, or simply fax to 631-273-0771. If you prefer to register by phone, please call 

631-273-0500 and our customer service staff will be glad to assist you.
For your convenience, record the following information below. The model and serial number can be found on a label located 

on the 

SANITRON

®

 Ultraviolet Water Purifier. Keep this manual, along with proof of purchase, handy when contacting our offices.

Purchased From:

Date:

Model:

Serial No.:

Summary of Contents for Sanitron S17A

Page 1: ...d Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Models S37C and S50C Installation Oper...

Page 2: ...ns when packaging equipment to prevent damage Care fully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 3: ...out proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the wat...

Page 4: ...cidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the q...

Page 5: ...a where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it...

Page 6: ...or with the optional wall mounting kit The purifier should not be solely supported by its plumbing connections 4 The water purifier must be connected to the cold water line only Inlet water temperatu...

Page 7: ...r Figure 4 NOTE Be sure to keep the large O Ring on the chamber head when removing this from the chamber 4 Remove PVC pipe and discard REMINDER be sure that the Teflon washer and O Ring from both ends...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve Figure 4 Initial Installation of Quartz Sleeve TELFON WIPER SEGMENTS GLAND FITTING QUARTZ SLEEVE WIPER ROD ASSEMBLY CHAMBER HEAD LARGE RUBBER O RING...

Page 9: ...in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of p...

Page 10: ...culty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency o...

Page 11: ...lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Reinstall lamp in reverse order Germicidal ultraviolet...

Page 12: ...is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push...

Page 13: ...static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end...

Page 14: ...ep ballast housing and mounting hardware in a clean dry area 2 Carefully remove as much of the broken quartz sleeve as possible from each end of the chamber 3 Remove chamber head clamp by using a 7 16...

Page 15: ...g located in the center of the disinfection chamber and protrudes into the chamber 1 Disconnect power to water purifier 2 Shut off water supply to the water purifier via the inlet and outlet shut off...

Page 16: ...tenance section Quartz sleeve sealing O Ring s worn damaged Shut down purifier drain and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance...

Page 17: ...dio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional Optional Optional Elapsed Time Indicator Optional Optional Optio...

Page 18: ...18 REPLACEMENT PARTS SANITRON Models S17A S23A Figure 11 Exploded View S17A S23A...

Page 19: ...15 Chamber 1 25 1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 151...

Page 20: ...20 SANITRON Models S37C S50C Figure 12 Exploded View S37C S50C...

Page 21: ...acer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...lamps and Other parts One 1 year Limited Warranty from the date of original purchase Within the warranty period we shall repair or replace such products which are returned to us with shipping charges...

Reviews: