9.  For Models with lamps packed separately, install lamp following the steps in 

“Lamp Installation or Replacement”

 section.

 Lamp and quartz sleeve are easily damaged. Exercise care when handling.

10. 

 

Plug water purifier into approved ground fault circuit interrupt (GFCI) receptacle. Confirm lamp 

operation indication at sight port. 

11.  Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing between the purifier 

and point of use. This is done by introducing chlorine or other disinfectant solution into the purifier chamber, a 100-ppm of 

chlorine is suggested. With the disinfectant in the purifier chamber, turn the ultraviolet purifier on. Open the “downstream” 

outlet until a chlorine or disinfectant solution odor is noticed. Close the outlet and allow the disinfectant to remain in the 

plumbing for three (3) hours. Flush the plumbing with ultraviolet purified water; allow the water to run for a minimum of 5 

minutes prior to use (to ensure no chlorine or disinfectant smell can be detected). This will allow the chlorine or disinfectant 

solution to be flushed from the pipes.

 

i

nitial

 i

nstallation

 

of

 Q

uartz

 s

leeve

 m

oDel

 s50C  

(s

hiPPeD

 

Without

 Q

uartz

 s

leeve

 i

nstalleD

)

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY 

EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

 Water Purifier should 

NOT be installed or plumbed prior to following the instructions on this page.

NOTE:

 Some 

SANITRON

®

 Model S50C models are packed without a quartz sleeve installed in the water purifier chamber and 

instead have a PVC pipe installed temporarily (for shipping purposes). Please follow these instructions if applicable.
1.  Pull off 

EASY-OFF

 End Caps from static gland nut on each end of the water purifier chamber.

2.  Unscrew static gland nuts from each end of the chamber and remove Teflon

®

 washer and O-Ring from both ends of PVC 

pipe. Set aside.

3.  Remove chamber head clamp from chamber and set aside. Withdraw Chamber head, wiper rod, and large head O-Ring in one 

assembly, making sure these parts remain together per 

Figure 4

NOTE:

 Be sure to keep the large O-Ring on the chamber 

head when removing this from the chamber. 

4.  Remove PVC pipe and discard (

REMINDER

: be sure that the Teflon

®

 washer and O-Ring from both ends of PVC pipe are 

removed before discarding the PVC pipe.) 

5. 

 Broken Quartz is SHARP.  It is recommended that protective glasses and gloves are worn when 

handling.

 Remove Quartz Sleeve from separate package inside the carton which had contained the water purifier.

6.  Starting from the end furthest away from the chamber head, carefully push the quartz sleeve 

(Figure 4)

 through each Teflon

®

 

wiper segment. Twisting the quartz sleeve will help perform this task. 

7.  Carefully align the end of the quartz sleeve with the gland fitting on the chamber head and pass the sleeve through the 

chamber head making sure the head O-Ring remains on the chamber head. 

 Broken Quartz is SHARP. It 

is recommended that protective glasses and gloves are worn when handling.

 

8.  Carefully slide the now-assembled head/ wiper/quartz sleeve assembly into the chamber. Support the far end of the quartz 

sleeve when passing it through the static gland nut. 

NOTE:

 

It is advisable to support the quartz sleeve on the opposite 

end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber.

 

9.  Push the chamber head/wiper assembly into the chamber until both flared ends (on the head and the chamber) mate  

against the O-Ring. 

10.  Place the clamp over the flared edges. 

IMPORTANT

 - Before tightening, be sure that wiper knob is at the 3 o’clock position 

(Figure 3)

. Tighten the nut until approximately 7/8” – 1” of the bolt protrudes past the nut.

11.  Center the quartz sleeve so equal lengths are protruding at each end past the gland fittings.
12.  Reassemble the O-Rings, Teflon

®

 washers and gland nuts in the order shown in 

Figure 3

TAKE CARE NOT TO 

DAMAGE THE QUARTZ SLEEVE WHEN INSTALLING THE GLAND NUTS. STRIKING THE SLEEVE WITH 

THE GLAND NUT WILL BREAK THE END OF THE QUARTZ SLEEVE.

13.  Tighten the static gland nuts firmly by hand. 

DO NOT USE HAND TOOLS

. Using hand tools is likely to 

cause quartz sleeve to break.

14.  Proceed to the “

Lamp Installation or Replacement

” section of this manual to properly install the germicidal ultraviolet 

lamp in the water purifier.

Summary of Contents for Sanitron S17A

Page 1: ...d Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Models S37C and S50C Installation Oper...

Page 2: ...ns when packaging equipment to prevent damage Care fully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 3: ...out proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the wat...

Page 4: ...cidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the q...

Page 5: ...a where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it...

Page 6: ...or with the optional wall mounting kit The purifier should not be solely supported by its plumbing connections 4 The water purifier must be connected to the cold water line only Inlet water temperatu...

Page 7: ...r Figure 4 NOTE Be sure to keep the large O Ring on the chamber head when removing this from the chamber 4 Remove PVC pipe and discard REMINDER be sure that the Teflon washer and O Ring from both ends...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve Figure 4 Initial Installation of Quartz Sleeve TELFON WIPER SEGMENTS GLAND FITTING QUARTZ SLEEVE WIPER ROD ASSEMBLY CHAMBER HEAD LARGE RUBBER O RING...

Page 9: ...in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of p...

Page 10: ...culty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency o...

Page 11: ...lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Reinstall lamp in reverse order Germicidal ultraviolet...

Page 12: ...is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push...

Page 13: ...static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end...

Page 14: ...ep ballast housing and mounting hardware in a clean dry area 2 Carefully remove as much of the broken quartz sleeve as possible from each end of the chamber 3 Remove chamber head clamp by using a 7 16...

Page 15: ...g located in the center of the disinfection chamber and protrudes into the chamber 1 Disconnect power to water purifier 2 Shut off water supply to the water purifier via the inlet and outlet shut off...

Page 16: ...tenance section Quartz sleeve sealing O Ring s worn damaged Shut down purifier drain and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance...

Page 17: ...dio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional Optional Optional Elapsed Time Indicator Optional Optional Optio...

Page 18: ...18 REPLACEMENT PARTS SANITRON Models S17A S23A Figure 11 Exploded View S17A S23A...

Page 19: ...15 Chamber 1 25 1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 151...

Page 20: ...20 SANITRON Models S37C S50C Figure 12 Exploded View S37C S50C...

Page 21: ...acer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...lamps and Other parts One 1 year Limited Warranty from the date of original purchase Within the warranty period we shall repair or replace such products which are returned to us with shipping charges...

Reviews: