Atlantic Ultraviolet Sanitron S17A Owner'S Manual Download Page 10

10

Table 3 - Optional Accessories

Optional Accessories

Available For:

GUARDIAN

 Ultraviolet Monitor - Analog/Digital

S17A through S50C

SENTRY

 Safety Sensor

S17A through S50C

STERALERT

 

Lamp Status Alarm

S17A through S50C

Promate

 Audio Alarm

S17A through S50C

Promate

 

Elapsed Time Indicator Universal Input

S17A through S50C

Promate

 

Wall Mounting Kit

S17A through S50C

Promate

 

Time Delay Mechanism

S17A through S50C

QUANTUM

 Thermal Optimizer:

S17A through S50C

Promate

 

Solenoid Valve

S17A

(3/4”)

S23A

(3/4”)

S37C

(1”)

S50C

(1-1/2”)

 

SureFLO

 Flow Control Valve

 

j

S17A

(3/4”)

S23A

(3/4”)

S37C

(1”)

S50C

(1-1/2”)

OPTIONAL ACCESSORIES

Most optional accessories are

available for operation at 120v 60Hz

or 220v 50Hz. Please specify.

Consult Factory for 12v DC or other

special input power requirements.

 

j

Unless otherwise specified PVC 

flow control valves are supplied. 

All PVC and Stainless Steel flow 

control valves are male NPT. 

Consult Factory for other flow 

control valves

MAINTENANCE

The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed 

maximum concentration levels, see “

Water Quality

” in the “

Product Application

” section. Ordinary maintenance consists of;

•  Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service.

•  Cleaning of the quartz sleeve, when conditions warrant. It is recommended that the inspection of quartz sleeve be performed after 

one month of use. If quartz sleeve is found to be coated (not clear), then frequency of cleaning must be done more often. Deposits 

or discoloration on the surface of quartz sleeve are caused by excessive levels of the subject contaminant within the water that 

is in contact with the quartz sleeve. Most deposits on the quartz sleeve are caused by an excess of calcium (hardness), iron or 

manganese. Table 1 on Page 4 lists the maximum recommended concentration of these minerals in the water that passes through 

the ultraviolet purifier. If you encounter difficulty due to deposits on the quartz sleeve, your dealer will be able to recommend 

suitable pretreatment to reduce or eliminate the offending contaminant. If quartz sleeve is clean (clear) then frequency of cleaning 

may be extended.

 NOTE: 

SANITRON

®

 Ultraviolet water purifiers are equipped with a manual wiping mechanism making 

the process of routine cleaning easier and therefore, recommended weekly or at the very least monthly to ensure best 

performance. NOTE: The use of optional 

GUARDIAN

 Ultraviolet Monitor will detect loss of transmission due to coating 

on the quartz sleeve.

•  Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below freezing.

•  Contact factory with questions.

i

nsPeCtion

1.  Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation.

•  On purifiers not equipped with the Ultraviolet Monitor, lamp operation can be verified by a visible glow through the 

translucent sight port. This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or 

transmission through the water.

•  On purifiers so equipped, the 

GUARDIAN

 Ultraviolet Monitor provides visual indication of the ultraviolet intensity 

through the quartz sleeve and water in the purifier chamber.

2.  To ensure proper operation of the water purifier, regular biological testing of the purifier output water should be performed on a 

schedule recommended by local public health authorities, or at minimum; at installation, quarterly for the first year of service and 

annually, at lamp replacement, for the life of the water purifier.

3.  Additional testing should be performed whenever modifications, change, or additions are made to plumbing system, pumps, well 

source water etc. to ensure adequate disinfection under new condition.

4.  As with any water purifier installation, routine maintenance is necessary to ensure you equipment is operating correctly. Regular 

inspection must also include confirmation that approved ground fault circuit interrupt (GFCI) receptacle is  

still operational and that water purifier is plugged into this GFCI. Any components which are damaged or broken  

should be replaced.

Summary of Contents for Sanitron S17A

Page 1: ...d Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Models S37C and S50C Installation Oper...

Page 2: ...ns when packaging equipment to prevent damage Care fully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 3: ...out proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the wat...

Page 4: ...cidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the q...

Page 5: ...a where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it...

Page 6: ...or with the optional wall mounting kit The purifier should not be solely supported by its plumbing connections 4 The water purifier must be connected to the cold water line only Inlet water temperatu...

Page 7: ...r Figure 4 NOTE Be sure to keep the large O Ring on the chamber head when removing this from the chamber 4 Remove PVC pipe and discard REMINDER be sure that the Teflon washer and O Ring from both ends...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve Figure 4 Initial Installation of Quartz Sleeve TELFON WIPER SEGMENTS GLAND FITTING QUARTZ SLEEVE WIPER ROD ASSEMBLY CHAMBER HEAD LARGE RUBBER O RING...

Page 9: ...in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of p...

Page 10: ...culty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency o...

Page 11: ...lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Reinstall lamp in reverse order Germicidal ultraviolet...

Page 12: ...is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push...

Page 13: ...static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end...

Page 14: ...ep ballast housing and mounting hardware in a clean dry area 2 Carefully remove as much of the broken quartz sleeve as possible from each end of the chamber 3 Remove chamber head clamp by using a 7 16...

Page 15: ...g located in the center of the disinfection chamber and protrudes into the chamber 1 Disconnect power to water purifier 2 Shut off water supply to the water purifier via the inlet and outlet shut off...

Page 16: ...tenance section Quartz sleeve sealing O Ring s worn damaged Shut down purifier drain and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance...

Page 17: ...dio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional Optional Optional Elapsed Time Indicator Optional Optional Optio...

Page 18: ...18 REPLACEMENT PARTS SANITRON Models S17A S23A Figure 11 Exploded View S17A S23A...

Page 19: ...15 Chamber 1 25 1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 151...

Page 20: ...20 SANITRON Models S37C S50C Figure 12 Exploded View S37C S50C...

Page 21: ...acer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...lamps and Other parts One 1 year Limited Warranty from the date of original purchase Within the warranty period we shall repair or replace such products which are returned to us with shipping charges...

Reviews: