10
Table 3 - Optional Accessories
Optional Accessories
Available For:
GUARDIAN
™
Ultraviolet Monitor - Analog/Digital
S17A through S50C
SENTRY
™
Safety Sensor
S17A through S50C
STERALERT
™
Lamp Status Alarm
S17A through S50C
Promate
™
Audio Alarm
S17A through S50C
Promate
™
Elapsed Time Indicator Universal Input
S17A through S50C
Promate
™
Wall Mounting Kit
S17A through S50C
Promate
™
Time Delay Mechanism
S17A through S50C
QUANTUM
™
Thermal Optimizer:
S17A through S50C
Promate
™
Solenoid Valve
S17A
(3/4”)
S23A
(3/4”)
S37C
(1”)
S50C
(1-1/2”)
SureFLO
™
Flow Control Valve
j
S17A
(3/4”)
S23A
(3/4”)
S37C
(1”)
S50C
(1-1/2”)
OPTIONAL ACCESSORIES
Most optional accessories are
available for operation at 120v 60Hz
or 220v 50Hz. Please specify.
Consult Factory for 12v DC or other
special input power requirements.
j
Unless otherwise specified PVC
flow control valves are supplied.
All PVC and Stainless Steel flow
control valves are male NPT.
Consult Factory for other flow
control valves
MAINTENANCE
The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed
maximum concentration levels, see “
Water Quality
” in the “
Product Application
” section. Ordinary maintenance consists of;
• Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service.
• Cleaning of the quartz sleeve, when conditions warrant. It is recommended that the inspection of quartz sleeve be performed after
one month of use. If quartz sleeve is found to be coated (not clear), then frequency of cleaning must be done more often. Deposits
or discoloration on the surface of quartz sleeve are caused by excessive levels of the subject contaminant within the water that
is in contact with the quartz sleeve. Most deposits on the quartz sleeve are caused by an excess of calcium (hardness), iron or
manganese. Table 1 on Page 4 lists the maximum recommended concentration of these minerals in the water that passes through
the ultraviolet purifier. If you encounter difficulty due to deposits on the quartz sleeve, your dealer will be able to recommend
suitable pretreatment to reduce or eliminate the offending contaminant. If quartz sleeve is clean (clear) then frequency of cleaning
may be extended.
NOTE:
SANITRON
®
Ultraviolet water purifiers are equipped with a manual wiping mechanism making
the process of routine cleaning easier and therefore, recommended weekly or at the very least monthly to ensure best
performance. NOTE: The use of optional
GUARDIAN
™
Ultraviolet Monitor will detect loss of transmission due to coating
on the quartz sleeve.
• Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below freezing.
• Contact factory with questions.
i
nsPeCtion
1. Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation.
• On purifiers not equipped with the Ultraviolet Monitor, lamp operation can be verified by a visible glow through the
translucent sight port. This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or
transmission through the water.
• On purifiers so equipped, the
GUARDIAN
™
Ultraviolet Monitor provides visual indication of the ultraviolet intensity
through the quartz sleeve and water in the purifier chamber.
2. To ensure proper operation of the water purifier, regular biological testing of the purifier output water should be performed on a
schedule recommended by local public health authorities, or at minimum; at installation, quarterly for the first year of service and
annually, at lamp replacement, for the life of the water purifier.
3. Additional testing should be performed whenever modifications, change, or additions are made to plumbing system, pumps, well
source water etc. to ensure adequate disinfection under new condition.
4. As with any water purifier installation, routine maintenance is necessary to ensure you equipment is operating correctly. Regular
inspection must also include confirmation that approved ground fault circuit interrupt (GFCI) receptacle is
still operational and that water purifier is plugged into this GFCI. Any components which are damaged or broken
should be replaced.