Atlantic Ultraviolet Sanitron S17A Owner'S Manual Download Page 16

16

10. 

Slowly 

restore water supply to the water purifier, pressurize, and check for leaks. Once it is determined that there are no 

leaks, inlet valve can be fully opened.

11.  Reposition Ultraviolet Monitor on probe body and tighten set screws.
12.  Restore power to the water purifier and ultraviolet monitor. If after the cleaning of the quartz rod, there is still no significant 

improvement in the ultraviolet intensity, as shown on the intensity meter, proceed to the 

“Troubleshooting”

 section.

TROUBLESHOOTING

 

Always disconnect power to the water purifier before performing any service or maintenance.

IMPORTANT

: This purifier is to be serviced 

ONLY

 by qualified, and appropriately licensed, personnel.

Table 4 - Troubleshooting

Problem

Possible Cause

Corrective Action

Purifier not operating

No electrical power

Verify that the purifier is connected to a live 

power source.

Water leaking from purifier

Cracked or broken quartz sleeve

Shut down purifier, drain, and replace quartz 

sleeve. See 

“Quartz Sleeve Installation or 

Replacement”

 in the

 “Maintenance”

 section

Quartz sleeve sealing O-Ring(s) worn, 

damaged

Shut down purifier, drain, and  remove static 

gland nut, replace sealing O-Ring. See 

“Quartz 

Sleeve Installation or Replacement”

 in the

 

“Maintenance”

 section

Poor, or loose, connections or fittings

Tighten suspect connection or fitting; or shut 

down purifier, drain, and remove fitting or 

connection. Clean threads; reapply thread sealing 

tape and reinstall.

Poor purifier disinfection performance  AND/OR Low 

UV intensity (As indicated on optional 

GUARDIAN

 

Ultraviolet Monitor)

Quartz sleeve fouled

Clean quartz sleeve, see “

Quartz Sleeve 

Cleaning

” in the “

Maintenance

” Section.

Sensor Probe, if equipped, lens or 

quartz rod fouled

Clean lens or Quartz Rod, see “

Optional 

Ultraviolet Monitor Sensor Probe Cleaning

” in 

the “

Maintenance

” section

Germicidal lamp output depreciating

Replace lamp, as it nears its end of life 

(EOL)

See “

Lamp Installation or Replacement

” in the 

Maintenance

” section.

Germicidal lamp not functioning

Replace lamp. See “

Lamp Installation or 

Replacement

” in the “

Maintenance

” section

Low input voltage

Verify input voltage to purifier.

Change in water quality

Have water tested to confirm that it does not 

exceed maximum recommended concentration 

levels for use with this purifier.

Summary of Contents for Sanitron S17A

Page 1: ...d Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Models S37C and S50C Installation Oper...

Page 2: ...ns when packaging equipment to prevent damage Care fully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 3: ...out proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the wat...

Page 4: ...cidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the q...

Page 5: ...a where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it...

Page 6: ...or with the optional wall mounting kit The purifier should not be solely supported by its plumbing connections 4 The water purifier must be connected to the cold water line only Inlet water temperatu...

Page 7: ...r Figure 4 NOTE Be sure to keep the large O Ring on the chamber head when removing this from the chamber 4 Remove PVC pipe and discard REMINDER be sure that the Teflon washer and O Ring from both ends...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve Figure 4 Initial Installation of Quartz Sleeve TELFON WIPER SEGMENTS GLAND FITTING QUARTZ SLEEVE WIPER ROD ASSEMBLY CHAMBER HEAD LARGE RUBBER O RING...

Page 9: ...in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of p...

Page 10: ...culty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency o...

Page 11: ...lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Reinstall lamp in reverse order Germicidal ultraviolet...

Page 12: ...is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push...

Page 13: ...static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end...

Page 14: ...ep ballast housing and mounting hardware in a clean dry area 2 Carefully remove as much of the broken quartz sleeve as possible from each end of the chamber 3 Remove chamber head clamp by using a 7 16...

Page 15: ...g located in the center of the disinfection chamber and protrudes into the chamber 1 Disconnect power to water purifier 2 Shut off water supply to the water purifier via the inlet and outlet shut off...

Page 16: ...tenance section Quartz sleeve sealing O Ring s worn damaged Shut down purifier drain and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance...

Page 17: ...dio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional Optional Optional Elapsed Time Indicator Optional Optional Optio...

Page 18: ...18 REPLACEMENT PARTS SANITRON Models S17A S23A Figure 11 Exploded View S17A S23A...

Page 19: ...15 Chamber 1 25 1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 151...

Page 20: ...20 SANITRON Models S37C S50C Figure 12 Exploded View S37C S50C...

Page 21: ...acer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...lamps and Other parts One 1 year Limited Warranty from the date of original purchase Within the warranty period we shall repair or replace such products which are returned to us with shipping charges...

Reviews: