Atlantic Ultraviolet Sanitron S17A Owner'S Manual Download Page 6

6

i

nstallation

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY 

EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

1.  Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there 

is any damage to the purifier, power cord or plug. Models S17A and S23A are shipped with the lamp already installed, while 

the lamp in the S37C and the S50C is packed separately. Keep the lamp aside for installation once the purifier has been 

properly installed.

2.  Purifiers occasionally experience damage in shipment due to the fragility of the quartz sleeve.  It is, therefore, recommended 

to inspect the water purifier for damage to the quartz sleeve after it has been removed from the shipping carton. Each end of 

the purifier as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz 

sleeve shows signs of damage it should be replaced before the purifier is pressurized.  See “

Quartz Sleeve Installation or 

Replacement”

 in the 

“Maintenance”

 section for the proper method of replacing the quartz sleeve in your water purifier.

Figure 2 - Recommended Installation

3.  The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting  holes 

in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its plumbing 

connections.

4.  The water purifier must be connected to the cold water line only. Inlet water temperature should not exceed 100

F.

5.  Installation requires that a 5-micron sediment filter or finer be installed, in line, prior to the water purifier. The sediment filter 

will stop or trap large particulates from entering the water purifier. Particulates may cause deposits on the quartz sleeve, as 

well as interfere with the purifier’s ability to disinfect the water. The sediment filter may also help to reduce the amount of  

routine cleanings of the quartz sleeve.

6.  Shut off valves should be installed on both the inlet and outlet sides of the water purifier. 

The use of bypass valves is not 

recommended

. The shut off valves allow the purifier to be isolated from the water supply, which is required when removing 

the quartz sleeve.

7.  Unions should be installed on both the inlet and outlet of the water purifier; this will allow easy removal of the water purifier 

from the plumbing, if required. Apply Teflon

®

 tape to threads of inlet and outlet ports to ensure a tight seal.

8.  When all plumbing connections are complete, allow water to enter the water purifier at a low flow rate, until the purifier is 

full. 

NOTE:

 Close the purifier outlet valve to pressurize the chamber.

 With the purifier pressurized, it should be checked 

for leaks. Once it is determined that there are no leaks, the inlet valve can be fully opened.  

(Continued on Page 7)

 

Summary of Contents for Sanitron S17A

Page 1: ...d Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Models S37C and S50C Installation Oper...

Page 2: ...ns when packaging equipment to prevent damage Care fully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 3: ...out proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the wat...

Page 4: ...cidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the q...

Page 5: ...a where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it...

Page 6: ...or with the optional wall mounting kit The purifier should not be solely supported by its plumbing connections 4 The water purifier must be connected to the cold water line only Inlet water temperatu...

Page 7: ...r Figure 4 NOTE Be sure to keep the large O Ring on the chamber head when removing this from the chamber 4 Remove PVC pipe and discard REMINDER be sure that the Teflon washer and O Ring from both ends...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve Figure 4 Initial Installation of Quartz Sleeve TELFON WIPER SEGMENTS GLAND FITTING QUARTZ SLEEVE WIPER ROD ASSEMBLY CHAMBER HEAD LARGE RUBBER O RING...

Page 9: ...in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of p...

Page 10: ...culty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency o...

Page 11: ...lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Reinstall lamp in reverse order Germicidal ultraviolet...

Page 12: ...is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push...

Page 13: ...static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end...

Page 14: ...ep ballast housing and mounting hardware in a clean dry area 2 Carefully remove as much of the broken quartz sleeve as possible from each end of the chamber 3 Remove chamber head clamp by using a 7 16...

Page 15: ...g located in the center of the disinfection chamber and protrudes into the chamber 1 Disconnect power to water purifier 2 Shut off water supply to the water purifier via the inlet and outlet shut off...

Page 16: ...tenance section Quartz sleeve sealing O Ring s worn damaged Shut down purifier drain and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance...

Page 17: ...dio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional Optional Optional Elapsed Time Indicator Optional Optional Optio...

Page 18: ...18 REPLACEMENT PARTS SANITRON Models S17A S23A Figure 11 Exploded View S17A S23A...

Page 19: ...15 Chamber 1 25 1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 151...

Page 20: ...20 SANITRON Models S37C S50C Figure 12 Exploded View S37C S50C...

Page 21: ...acer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...lamps and Other parts One 1 year Limited Warranty from the date of original purchase Within the warranty period we shall repair or replace such products which are returned to us with shipping charges...

Reviews: