Manual, FT Sensor, Ethernet Axia
Document #9610-05-Ethernet Axia-05
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
• Email:
56
The F
z
T
xy
equation simplifies as follows:
Because the F
xy
T
z
equation simplified to TRUE, bit 30 in
10.8 Diagnostic Monitoring
During operation, the Ethernet Axia firmware monitors the hardware. When power is applied to the sensor,
the firmware waits (5) seconds before evaluating the supply voltage for errors. The following table lists
status messages.
Table 10.7—Status Messages During Monitoring
Message
Supply Voltage out of range.
Gage Temperature out of range.
Calibration checksum error.
Gage(s) disconnected: <list>
Gage(s) out-of-range: <list>
Force/torque out of range
Common error.
Simulated error.
Monitor Condition 0.
Error (unspecified)
Good (no status code errors)
The following table lists the system health indicators that the Axia FT firmware monitors.
Table 10.8—Network Health System
Indicator
Description
Stack Usage
The maximum amount of the stack usage is continuously monitored. An error
message is generated if the available stack is too low.
MCU Program
Memory CRC
The CRC of the MCU program flash memory is continuously monitored. An
error message is generated, if an error is found.
Parameter
Memory CRC
The CRC of the MCU RAM Parameter Memory, which is used to store the
calibration, is continuously monitored. An error message is generated, if an
error is found.
MCU Data
Memory Test
The MCU Data Memory (RAM) is continuously tested. An error message is
generated, if an error is found.