Table 3.1—Sensor Cable Bending Radius and Dynamic Twist Angle
Cable Part Number
Spliced Cable
Branch
Description
Cable
Diameter
mm (in)
Static
Bending
Radius
(at room
temperature)
Dynamic
Bending
Radius
(at room
temperature)
Dynamic
Cable Twist
Angle per
Unit Length
mm
in
mm
in
9105-C-ZC22-ZC26-X
N/A
7 (.28)
35
1.4
70
2.8
180°/m or
55°/ft
9105-C-ZC26-U-
RJ45S-X
Branch 1,
Power
5.1 (.20)
25.5
1
51
2
Branch 2,
Ethernet
5.7 (.22)
28.5
1.1
57
2.2
Notes:
1.
Temperature affects cable flexibility. ATI recommends increasing the minimum dynamic bending radius for
lower temperatures.
The 6-pin 9105-C-ZC22-ZC26-X cable attaches to the sensor’s connector. The
9105-C-ZC26-U-RJ45S-X
8-pin connector attaches to the 9105-C-ZC22-ZC26-X power and Ethernet cable, of which branch 1 is an
unterminated end for power and branch 2
has
a RJ45 connection for Ethernet.
Route the sensor cable so that it is not stressed, pulled, kinked, cut, or otherwise damaged throughout the
full range of motion. If the application causes cable abrasion, use a loose plastic, spiral wrap to protect the
outer cable jacket material.
CAUTION:
Do not damage or crush the cable by over tightening tie wraps on the cable.