Manual, FT Sensor, Ethernet Axia
Document #9610-05-Ethernet Axia-05
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
• Email:
53
Table 10.4—Calibration
Field
Name
Type
Description
gca0 to gcc7
Reserved.
gageMaxRange GageMaxRange
Numeric.
Gage strain levels equal to this
value and greater are out of range.
gageMinRange
GageMaxRange
Numeric.
Gage strain levels equal to this
value and lower are out of range.
peakPos0
PeakLoadsPosFx
Numeric.
Peak Loads Positive. All-time peak
positive force/torque, in counts.
peakPos1
PeakLoadsPosFy
peakPos2
PeakLoadsPosFz
peakPos3
PeakLoadsPosTx
peakPos4
PeakLoadsPosTy
peakPos5
PeakLoadsPosTz
peakNeg0
PeakLoadsNegFx
Numeric.
Peak Loads Negative. All-time
peak negative force/torque, in
counts.
peakNeg1
PeakLoadsNegFy
peakNeg2
PeakLoadsNegFz
peakNeg3
PeakLoadsNegTx
peakNeg4
PeakLoadsNegTy
peakNeg5
PeakLoadsNegTz
GuA to GuB
Reserved.
tca to tce
sensorHwVer
sensorInstr
paramWrites
adcRate
ADC Sample
Rate
Numeric.
The ADC update rate in Hz. The
rate must be 488, 976, 1953,
3906, or 7912 Hz.
rdtRate
RDT Protocol
Output Rate
Numeric.
The RDT transmission rate in Hz.
The rate must be 1 to adcRate
Hz.
rdtSize
RDT Buffer Size
Numeric.
The number of RDT records to
include in each buffered UDP
packet transmitted.
filTC
Filter Selection
Numeric.
The IIR filter shift value. Allowable
.
calib
Calibration
Selection.
Numeric.
The calibration to use: 0 or 1.
location
Sensor Location
STRING(40)
The location of the sensor on the
network.
serNum
Serial Number
STRING(100)
The serial number.
hwProdCode
HW Product Code STRING(20)
The hardware product code.
sipmode
Static IP Mode
Numeric.
Static IP mode:
1 = Static
0 =DHCP