Monthly/ Six Monthly / Yearly Routine Maintenance
Visually inspect the Remote Vacuum Sensor box for damage. Any damage will admit water causing the
premature failure of the electronics and should be fixed as soon as possible.
Parlour Wash Down
The Remote Vacuum Sensor control enclosure is IP65 rated. However, no indirect or direct pressure
washing should be used to wash the Remote Vacuum Sensor Control, as this will cause the seals to fail
and water to ingress and damage the electronic components. Please note that water damage is not
covered under warranty.
Troubleshooting
The Remote Vacuum Sensor reports errors to the user. If an error occurs the control show the error on
the screen, pressing the Idle key will clear the error.
The list is a list of the errors which may occur on the Remote Vacuum Sensor.
Error
Fault Information
Warning: Low
Vacuum Level
The vacuum level measured was lower than the low warning level for this
milking or washing.
Warning High
Vacuum Level
The vacuum level measured was higher than the high warning level for this
milking or washing.
Error: Vac Pump X
Is in manual mode
The system attempted to start the vacuum pump, however it was switched into
manual mode. Where X is the number of the vacuum pump.
Error: Vac Pump X
Comms Error
The system could not communicate with the vacuum pump. Where X is the
number of the vacuum pump.
Error: Vac Pump X
Over-current
The vacuum pump reported that it has entered an over-current state. Where X
is the number of the vacuum pump.
Error: Vac Pump X
Over-voltage
The vacuum pump reported that it has entered an over-voltage state. Where X
is the number of the vacuum pump.
Error: Vac Pump X
Overheat
The vacuum pump reported that it has entered an overheat state. Where X is
the number of the vacuum pump.
Error: Vac Pump X
Dyn Break fault
The vacuum pump reported that a dynamic breaking fault has occurred. Where
X is the number of the vacuum pump.
Error: Vac Pump X
PID Feedback
The vacuum pump reported that a PID feedback fault has occurred. Where X is
the number of the vacuum pump.
Error: Vac Pump X
External Fault
The vacuum pump reported that an external fault has occurred. Where X is the
number of the vacuum pump.
Error: Vac Pump X
Hardware Fault
The vacuum pump reported that a hardware fault has occurred. Where X is the
number of the vacuum pump.
Error: Vac Pump X
Motor Overload
The vacuum pump reported that a motor overload fault has occurred. Where X
is the number of the vacuum pump.