20
| Remote Vacuum Sensor Manual | v1.0
The Vacuum Setup Menu Structure Continued
The M2Bus Settings Menu Structure
The M2Bus setup menu is structured as shown below;
Entry point into M2Bus setup menu.
Innovation In and Out of Parlour
©
A
TL
A
g
ricu
ltu
ra
l
Te
ch
n
olog
y
L
imite
d:
Ju
n
e
2
0
1
6
ê
ê
ê
ê
Wash Vacuum Low: This is the level at which after 1
minute of operation the unit will warn the user if the
vacuum drops below this level. This level can be
increased by pressing the Idle key, and decreased by
pressing the Milk key. Press the Wash key to store the
setting and return to the main menu.
Wash Vacuum
Low: 42.0kPa
The Vacuum Settings main menu item.
RVS Settings
Vacuum Settings >
M2Bus Settings Address: This setting allows the user to
enter the address of the unit on the M2Bus. This number
can be increased by pressing the Idle key, and
decreased by pressing the Milk key. Press the Wash key
to store the setting and move to the next setting.
M2Bus Settings
Address: 1
M2Bus Settings Milking Point Control: Yes / No. This
setting enables or disables communications with the
Milking Point Controls. Press Idle to set to No, Milk to set
to Yes. Press the Wash key to store the setting and move
to the next setting.
M2Bus Settings
Milking Pt Ctrl: No
M2Bus Settings Milk Pump: Yes / No. This setting
enables or disables communications with the Milk Pump
control. Press Idle to set to No, Milk to set to Yes. Press
the Wash key to store the setting and move to the next
setting.
M2Bus Settings
Milk Pump: No
ê
Settings continued on next page.