The Vacuum Setup Menu Structure
The vacuum setup menu is structured as shown below;
Entry point into vacuum setup menu.
Innovation In and Out of Parlour
©
A
TL
A
g
ricu
ltu
ra
l
Te
ch
n
olog
y
L
imite
d:
Ju
n
e
2
0
1
6
ê
ê
ê
ê
ê
Enable VP1: Yes / No. This setting enables or disables
vacuum pump 1. Press Idle to set to No, Milk to set to
Yes. Press the Wash key to store the setting and move to
the next setting.
Vacuum Settings
Enable VP1: Yes
Enable VP2: Yes / No. This setting enables or disables
vacuum pump 2. Press Idle to set to No, Milk to set to
Yes. Press the Wash key to store the setting and move to
the next setting.
Vacuum Settings
Enable VP2: No
Enable VP3: Yes / No. This setting enables or disables
vacuum pump 3. Press Idle to set to No, Milk to set to
Yes. Press the Wash key to store the setting and move to
the next setting.
Vacuum Settings
Enable VP3: No
Milking Vacuum Level: This setting is the level of
vacuum to be maintained during the milking. This level
can be increased by pressing the Idle key, and
decreased by pressing the Milk key. Press the Wash key
to store the setting and move to the next setting.
Milking Vacuum
Level: -46.0kPa
Milking Vacuum High: This is the level at which after 1
minute of operation the unit will warn the user if the
vacuum increases beyond this level. This level can be
increased by pressing the Idle key, and decreased by
pressing the Milk key. Press the Wash key to store the
setting and move to the next setting.
Milking Vacuum
High: -50.0kPa
ê
Settings continued on next page.