English
15
a
WARNING: The use of unsuitable parts,
and/or the implementation of installation
procedures other than those shown on the
installation diagram, will immediately void
the machine warranty.
The characteristics of the electricity network must
be compatible with the values required for correct
operation indicated on the machine identification plate
and on the technical data sheet.
The machine must be connected to an efficient earthing
system (according to electrical safety standards).
Ö
The manufacturer is not to be held liable for
any damage caused by improper earthing of
the machine or faulty power supply.
2,
5
2,
5
5
0
TT = 650 UC = 820
Fig. 7
5.1 Built-in installation
The built-in machine can be inserted under a continuous
worktop or under the sink’s drip surface. The recess
niche must have a minimum space as shown in figure 7.
The presence of adequate air intakes must be
guaranteed to allow the ventilation of the area behind
the machine, in order to avoid creating a closed space
without exchange of air with the room environment.
5.2 Stand-Alone Installation
If the UC machine is positioned isolated with respect to
a worktop, i.e. it is resting on its feet and not inserted in
a niche, it is important to remember to fix the machine
to the ground using plugs or equivalent fixings to
ensure that it is not overturn if pushed on its longer
side. The lower compartment contains holes that can
be used to perform this operation.
a
The manufacturer declines any liability for
damage to things and/or people caused by
the machine falling due to the fact that it is
not fixed to the ground.
5.3 Electrical connection
b
HAZARD. Only qualified and experienced
personnel can connect the machine to the
mains supply, in compliance with the current
laws and regulations.
a
WARNING: In the single-phase version, the
main switch of the power supply line must be
a multi-pole circuit breaker, with adequate
residual current protection.
a
WARNING: In the three-phase version,
the main switch must be multi-pole circuit
breaker, with adequate residual current
protection, positioned near the machine and
not covered by machines or other that may
hinder its use.
The magnetic-snap safety system, or the fuses, must
be calibrated according to the power indicated on the
machine plate.
- Make sure that the measured voltage is equal to
the one reported on the identification plate of the
machine;
- Check that the voltage does not differ by more than
10% from its rated value;
- Make sure that the electrical system is equipped with
an efficient earthing connection;
- Connect the cable that comes out of the machine
to the wall socket. In case the machine has a three-
phase connection (on request), connect the cable
installed on the machine to the three-phase plug (not
supplied) and insert it into the interlocked socket next
to the machine (not provided).
- The socket must be accessible after the machine
installation. This facilitates verification of the electrical
safety, e.g. in repair or maintenance interventions.
- The machine must be supplied with current whose
voltage, frequency and protection values correspond
to those indicated on the data plate.
- The wiring diagram can be downloaded from the
manufacturer’s website. Additional indications