5-26
Chapter 5: BIOS setup
Flow Control [Hardware RTS/CTS]
Flow control can prevent data loss from buffer overflow. When sending data, if the receiving
buffers are full, a “stop” signal can be sent to stop the data flow. Once the buffers are empty,
a “start” signal can be sent to re-start the flow. Hardware flow control uses two wires to send
start/stop signals. Configuration options: [None] [Hardware RTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100 terminals.
Configuration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
This allows you to enable or disable the Recorded mode to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Resolution 100x31 [Enabled]
This allows you to enable or disable the extended terminal resolution. Configuration options:
[Disabled] [Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Configuration options: [80x24] [80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty. Configuration options:
[VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]
Redirection After BIOS POST [Bootloader]
This setting allows you to specify if Bootloader is selected than Legacy console redirection.
Configuration options: [Always Enable] [Bootloader]
Serial Port for Out-of-Band Management/Windows Emergency Management
Services (EMS) Settings
The following items only appears when you set the
Console Redirection
to [Enabled].
Out-of-Band Mgmt Port [COM1]
Allows remote management of a Windows Server OS through a serial port. Configuration
options: [COM1] [COM2]
Terminal Type [VT-UTF8]
Allows you to set the terminal type for out-of-band management. Configuration options:
[VT100]
ASCII char set.
[VT100+]
Extends VT100 to support color, function keys, et.
[VT-UTF8]
Uses UTF8 encoding to map Unicode chars onto 1 or more bytes
[ANSI]
Extended ASCII char set
Bits per second [115200]
Selects serial port transmission speed. The speed must be matched on the other side. Long or
noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400] [57600]
[115200]
Flow Control [None]
Allows you to set the flow control to prevent data loss from buffer overflow. Configuration options:
[None] [Hardware RTS/CTS] [Software Xon/Xoff]
Summary of Contents for TS300-E8-RS4-C
Page 1: ...Pedestal 5U Rackmount Servers TS300 E8 RS4 C User Guide ...
Page 22: ...Chapter 1 Product introduction 1 10 ...
Page 59: ...ASUS TS300 E8 RS4 C 4 3 4 1 3 Motherboard layout ...
Page 138: ...6 18 Chapter 6 RAID configuration ...
Page 166: ...7 28 Chapter 7 Driver installation ...
Page 170: ......