![Astoria 2GR Use And Maintenance Manual Download Page 89](http://html.mh-extra.com/html/astoria/2gr/2gr_use-and-maintenance-manual_2990323089.webp)
89
of
92
TECHNICIANS manual
ENGLISH
No.
PARA.
DESCRIPTION
47
GR3 HEATING UNIT TEMPERATURE SETPOINT
IN STANDBY
-
76
MAXIMUM FLOW VARIATION PERCENTAGE
5 ÷ 100
101
T1 AUTOSTEAMER TEMPERATURE SETPOINT
50 ÷ 80 °C
102
T2 AUTOSTEAMER TEMPERATURE SETPOINT
50 ÷ 80 °C
103
T3 AUTOSTEAMER TEMPERATURE SETPOINT
50 ÷ 80 °C
104
AUTOSTEAMER DELIVERY TIMEOUT
0 ÷ 600 sec
111
CONDENSATE DRAIN TEMPERATURE
100 ÷ 115 °C
125
PRE-WARNING BOARD
TEMPERATURE SETPOINT
0 ÷ 90 °C
133
DELAY OF LAST DELIVERY PERFORMED
DUE TO STANDBY ACTIVATION (sec)
0 ÷ 255 min
134
DELIVERY TIME THRESHOLD TO
ACTIVATE STANDBY MODE
1 ÷ 250
141
GR1 KEYBOARD LAYOUT
0 ÷ 3
142
GR2 KEYBOARD LAYOUT
0 ÷ 3
143
GR3 KEYBOARD LAYOUT
0 ÷ 3
144
GR4 KEYBOARD LAYOUT
0 ÷ 3
174
AUTOSTEAMER WASH DELAY SINCE
LAST DISPENSED BEVERAGE
0 ÷ 240 min
175
SOLENOID VALVE ACTIVATION TIME
DURING AUTOSTEAMER WASH
0 ÷ 2 sec
176
SOLENOID VALVE DEACTIVATION TIME
DURING AUTOSTEAMER WASH
0 ÷ 3 sec
177
NUMBER OF ON/OFF CYCLES PER
AUTOSTEAMER WASH
1 ÷ 10
178
KEY ENABLE “Dosing programming”
0 = Disabled
1 = Enabled
179
KEY ENABLE “Last dispensed beverage graph”
0 = Disabled
1 = Enabled
180
KEY ENABLE “Service parameters”
0 = Disabled
1 = Enabled
181
KEY ENABLE “Set time/date”
0 = Disabled
1 = Enabled
182
KEY ENABLE “Washes”
0 = Disabled
1 = Enabled
183
KEY ENABLE “Blend selection”
0 = Disabled
1 = Enabled
184
KEY ENABLE “Theme”
0 = Disabled
1 = Enabled
185
KEY ENABLE “Screensaver”
0 = Disabled
1 = Enabled
186
KEY ENABLE “Counter list”
0 = Disabled
1 = Enabled
187
KEY ENABLE “Filters”
0 = Disabled
1 = Enabled
188
KEY ENABLE “Service shortcut parameters”
0 = Disabled
1 = Enabled
189
STANDBY MODE
0 = Energy saving
1 = OFF
190
MANUAL DISPENSING KEY
0 = single
1 = double
No.
PARA.
DESCRIPTION
311
BAUD RATE FOR THE RS232
CN12 SERIAL (register)
0 = 1200 Baud
1 = 2400 Baud
2 = 4800 Baud
3 = 9600 Baud
4 = 19200 Baud
5 = 38400 Baud
312
PARITY FOR SERIAL PORT
RS232 CN12 (register)
0 = None (with 2
stop bits)
1 = ODD (1 stop bit)
2 = EVEN (1 stop
bit)
3 = NONE (1 stop
bit)
313
COMMUNICATION TIMEOUT FOR
RS232 CN12 (register)
0,1 ÷ 60 sec
354
BRIGHTNESS BACKLIGHT DISPLAY GROUP 1
1 ÷ 100 %
355
BRIGHTNESS BACKLIGHT DISPLAY GROUP 2
1 ÷ 100 %
356
BRIGHTNESS BACKLIGHT DISPLAY GROUP 3
1 ÷ 100 %
357
BRIGHTNESS BACKLIGHT DISPLAY GROUP 4
1 ÷ 100 %
370
DEMO MODE ACTIVATION
0 = Disabled
1 = Enabled
375
AQUEDUCT DISCHARGE PRESSURE
(FRC MACHINE ONLY)
0 ÷ 15 bar