TECHNICIANS manual
ENGLISH
Code
Warning
Cause
Action
M072
WARNING: Maintenance threshold B
•
The programmed threshold for maintenance
has been reached.
•
Perform scheduled maintenance.
M073
WARNING: Maintenance threshold C
pre-warning
•
The programmed threshold for maintenance
has been reached.
-
M074
WARNING: Maintenance threshold C
•
The programmed threshold for maintenance
has been reached.
•
Perform scheduled maintenance.
M075
WARNING: Service Plan pre-warning
•
The programmed threshold for Service Plan
maintenance has been almost reached.
-
M076
WARNING: Service Plan
•
The programmed threshold for Service Plan
maintenance has been reached.
•
Perform scheduled maintenance.
M077
WARNING: It is advisable to manually
empty the steam heating unit
•
The water in the heating unit needs to be
regenerated.
•
Perform the relative procedure.
M100
WARNING: Release water and steam
•
Release water and steam from the group to
remove any air in the coffee heating unit.
•
Wait for the process to finish (10 seconds).
M101
WARNING: Steam outlet
•
Release steam from the tea spout to remove
any air in the heating unit.
•
Wait for it to automatically close.
M102
WARNING: Coffee heating unit water
replacement in progress
•
The water in the heating unit needs to be
regenerated.
•
Perform the relative procedure.
M1031
WARNING: Basic communication not
found timeout
•
Communication error.
•
Check how many groups have been set in the
machine.
•
Switch the machine off and back on again (but
not whilst updating).
If the problem cannot be resolved, switch off the machine and contact the Manufacturer.