TECHNICIANS manual
8.14
Menu calibration (FRC)
Through this menu,
it is possible to calibrate
the lever positioning
and group Pumps, in
models with delivery
lever (FRC).
8.14.1 Lever
calibration
Proceed as follows:
•
a c c e s s t h e f i r s t
screen, and bring the
lever to a fully raised
position, then press
“save”;
•
wait for the second
screen, then lower
the lever complete-
ly, and press “save”
again.
Perform the calibra-
tion for each group.
It is essential to have the
lever installed on the FRC machine and with the lever set in
analogue mode.
The value shown during calibration does not impact normal
operation.
8.14.2 Group pump calibration
Proceed as follows
:
•
Insert the special filter holder;
•
Select the "START" button;
•
Wait for the calibration procedure to complete;
The calibration of the pump must be carried out using the group
display.
save
523
LEVER CALIBRATION
SERVICE SETTINGS
Maintenance
View delivery
Recipe library
Software
Washes
Language
Parameter list
Energy saving
& cloud
Service
parameters
Coffee
temperatures
Water filters
Menu
calibration
LEVER CALIBRATION
850
save
STEP 1 calibration
Stop
GROUP PUMP CALIBRATION
STEP 2 calibration
Stop
GROUP PUMP CALIBRATION
Pump calibration OK
Stop
GROUP PUMP CALIBRATION
Starting calibration ?
Start
GROUP PUMP CALIBRATION