28
attached to a flat heating plate without wrinkles.
Replacing the cloth plate,
The heating plate back into the machine.
5).the replacement of silicone
Must be checked once every week for wear or damage silicone, silicone once
becomes uneven, to be replaced immediately silicone.
Average maintenance cycle for silicone at least once every six months.
Silicone is stuck in the seat, you can unscrew the four screws directly withdrawn
after the pressure of the support plate.
Release the pressure of the support plate screws and remove the pressure of the
support plate.
The old silicone withdrawn from the silicone base.
Cut a new silicone, the same length as the old one, and ensure the consistent size
of the old silicone.
The new silicone loaded silicone base, and attach the batten support plate.
Silicone must be completely flat on the silicone seat. It is very important that the
silicone is smooth in place and there is not tension phenomenon.
Description: one side of silicone rubber is textured, but the other side is textured with
a fixed hole. Printing particles can be installed for printing labels. Select the desired
side of silicone to use.
6), Replace the seals
Seal ring is to seal the vacuum chamber during operation, this is very important for
vacuum degree. Due to different pressures, seals wear out and must be replaced
regularly.
Check the seals at least once a week to see if there is wear or damage.
The average maintenance cycle of the sealing ring at least once every six months.
Seal is stuck in the vacuum chamber lid tank and it can be put out directly. The new
seal length can be according to the old seal strip, too long or too short can cause
the lid cannot be closed or leak.
Put the new seal ring into the vacuum chamber lid groove.
Ring should be placed flat, no tension phenomenon, the end must be cut straight,
and compact to prevent leakage.
8.Failure Analysis and solutions
1).Machine failure and solutions
Problem status
Caused by reason
Solutions
Machine not work,
control panel not
show information
No connect voltage
Power on
Mainly circuit fuse broken
Replacement right size fuse
Power switch touch point loose
Check-fixed-repair-or
replacement
Control panel start,
machine not work
Vacuum chamber inside sensitive
switch position not right or broken
Adjust or replace new
sensitive switch
Setting parameter
Finished parameter setting
Machine inside problem
Contact manufacture or