sealing.
computer board panel program settings:
No.
Sample
Operate
Display
1
Power on
Show "-" or "Ed"
Show "-" or "Ed"
2
Function is selected, the
corresponding function lights (red).
It is vacuum time, inflation time (if
have), sealing time, cooling time.
Display the selected
parameter setting
functions.
3
Press once, the parameters of the
selected function program to increase
per unit of time.
Press and hold the button will
increase value at a rate of about 5
values per second.
Display the selected
parameter setting
functions.
4
Press the function selection button
one or more times, until all the
function lights go out, the machine
will save the parameters.
Display "-" or "Ed"
Each function parameter adjustment range:
Function name
Parameter range
Adjustment
Unit
Vacuum
0-99
1
Second
Inflatable
0-9.9
0.1
Second
Sealing
0-6
0.1
Second
Cooling
0-6
0.1
Second
Select temperature setting
No.
Sample
Operate
Display
1
Power on
Show "-" or "Ed"
Show "-" or "Ed"
2
Press one time the display right indicator
show high-medium-low temperature
Show "-" or "Ed"
3
When using the temperature selector
button to select a certain temperature, the
corresponding temperature indicator light
(red).
If the high, medium and low three lights are
off, it will not be sealed.
Show "-" or "Ed"
4).Optimal parameters
Vacuum time should be determined according to the number or size of the vacuum
chamber and the volume of the material. usually, the vacuum function can be set at
between 20 and 40 seconds. If the degree of vacuum is not lower than 0.06Mpa and
then began sealing, the sealing function may not be completed properly.
special packaging for the product may be appropriate to extend the vacuum time.
For example, a relatively high moisture content of the packaging, and other liquids.