(BESA-12V24G) User Manual
Version GS 17628
15
Version GS 17628
Interpretation of Results:
The battery is in good condition.
The battery is OK but need to recharge first in order to have the maximum
performance.
The battery is weak, need to be replaced with a good one.
The battery need to recharge first and then test again to confirm the final
results.
2. Volts : 12.55V (State of Charge [SOC])
The volts here indicated the State of Charge (SOC) of the tested battery which is 12.55V during open
circuit condition. [By referring to the table below, this battery is above 50% SOC]
-
3. Battery Rating: 180 CCA
The battery capacity rated output is normally stated on the label for car batteries (either in CCA, EN, DIN,
JIS, etc.). For batteries with model numbers, please refer the charts provided with the Analyser.
4. Power available: 120 CCA
It means that the battery tested has a capacity of 120 CCA power available. CCA ratings has been used
here, therefore the tested result is in CCA and if other rating (DIN, SAE, JIS, IEC, CA, or EN) were
selected, it will base on the respective rating to calculate and show the results in that selected rating.
State Of
Charge(SOC)
WET/SLI
AGM
GEL
100 %
12.60 V
12.80 V
12.85 V
90 %
12.58 V
12.72 V
12.77 V
80 %
12.44 V
12.64 V
12.69 V
75 %
12.40 V
12.60 V
12.65 V
50 %
12.20 V
12.30 V
12.35 V
25%
12.00 V
12.00 V
12.00 V
0%
11.80 V
11.80 V
11.80 V
Flashing
Flashing
Flashing