7-7
SORGENTE/SMILE/ISI-T/UNDERCOUNTER - Installation, Use and Maintenance - cod. A-MAN03 - Rev. 02/2012
7.3.3
Set Check
To check the correct set value it will be necessary to press
the rear programming key and count the number of beeps.
7.3.4
Signallings and acoustic alarms
Filter exhaustion pre-alarm:
2 beeps every 15 seconds. The beeps repeat every time
a dispensing key is pressed.
Refrigerator alarm:
If for technical reasons or for possible clogging in the
heating exchanger,
the cooling system should not reach
the pre-set temperature in 6 hours
, the cooling system
must be switched off and the water dispensing interrupted.
In this case, will appear a fixed red Led 2 positioned above
the right key, (cold water dispensing) followed by 7 beep
every 15 seconds; moreover, every time the dispensing
keys are pressed the 7 beep are repeated.
Filter exhaustion pre-alarm:
This function follows the filter pre-alarm A1.
The machine
is blocked when the filter is completely exhausted
.
In this case, the red Led 1 above the left dispensing key
(room temperature water dispensing) starts to blink and
it is followed by a 15 seconds long beep which will be
repeated each time the dispensing keys are pressed.
The
machine could be restarted only by replacing the filter
and inserting the smart card, supplied with the new
filter, in the proper fissure, see paragraph 8.3.
Pump blockage.
In case the pump is not able to restore the water level
in the carbonator in 3 minutes,
the pump is blocked to
avoid any damages
. In this phase will appear a fixed
red Led 2 on the right, positioned above the right key
(cold still water dispensing), followed by 6 beep every
15 seconds.
smart card wrong insertion error.
The machine will not accept the smart card put in a wrong
way. By inserting the smart card, in the right way, a 5
long beep will be heard and OK will appear on the display.
Then take out the smart card.
ATTENTION: The remote control keypad is operating cor-
rectly when the red operation led lights on when any key
is pressed.