5-5
SORGENTE/SMILE/ISI-T/UNDERCOUNTER - Installation, Use and Maintenance - cod. A-MAN03 - Rev. 02/2012
5.4.4
Connection of internal CO
2
bottle
The dispenser comes with the internal monouse CO
2
bottle
(optional)
deliberately NOT completely screwed on the
pressure reducer
; this is to prevent the emptying of the
bottle during transport.
CAUTION: Do not expose hands or any other part of the
body to the gas because it could cause freeze burns.
First, screw the pressure reducer on the CO
2
bottle.
With one hand clutch the pressure reducer and with the
other hand screw completely the CO2 bottle keeping it
vertical, turning it clockwise (fig. 5.4).
A possible gas leakage during the set up or replacement
operation is normal.
Instead a continuous gas leakage is not normal after the
complete screwing up of the bottle.
If the gas leakage does not end, lock strongly the bottle
to the reducer or replace the sealing gasket.
If necessary call the technical assistance.
Check that there are no CO2 leakages.
Then reposition the bottle in the appropriate support
binder paying attention that the plastic connection tube
is not flattened or stretched
(fig. 5.5)
.
Re-position the front panel of the dispenser.
Note: The dispenser is ready to dispense 2 hours after
the start up.
fig.5.4
CAUTION
Do not expose hands or any other
part of the body to the gas because
it could cause freeze burns.
fig.5.5